Figure 12. functional configuration screen -6 – CANOGA PERKINS 2370 High-Speed Universal Fiber Optic Modem User Manual
Page 34
 
-------------------------FUNCTIONAL CONFIGURATION------------------------- 
 Local Pri. Local Sec. Remote Pri. Remote Sec. 
 
Oscillator(MHz) 6.144 6.144 6.144 6.144 
Interface Type EIA-423/232 EIA-423/232 EIA-530 EIA-530 
Operating Mode Internal Internal Slave Slave 
Int. Rate (bps) 384000 384000 384000 384000 
TD Timing SCTE SCTE N/A N/A 
RD Timing SCR SCR SCT SCT 
DCD Output Far RTS Far RTS CLS CLS 
CTS Output Local RTS Local RTS Remote DTR Remote DTR 
DSR Output Far Local Test Far Local Test Any Test On Any Test On 
KGCTS(A)/RLSD Normal Normal +6V/GND +6V/GND 
Delay (ns) N/A N/A N/A N/A 
T1 Output N/A N/A N/A N/A 
LOS Detection On On On On 
Redundancy Auto/Active Auto/Inactive Auto/Active Auto/Inactive 
 
Select [1] to configure local interface, [2] to configure remote interface, 
[3] LOS Detection, [4] redundancy setup: 
Figure 12. Functional Configuration Screen
Table 12. Functional Configuration Option Definitions
Menu Item
Description
1) Configure local interface
Enter values for the local interface parameters
2) Configure remote interface Enter values for the remote interface parameters 
3) LOS Detection 
Set to On or Off
4) Redundancy setup
Set to Auto, Manual Primary (Man Pri) or Secondary (Man Sec), 
or Off; shows current activity 
You can set values for various parameters for both local and remote modems. To configure an 
interface, see Tables 12 and 13 and follow these steps: To configure the 2370 functions, follow these 
steps: 
1. From the Main Menu type 2, "Functional Configuration," and press <Enter>.
2. From the Functional Configuration menu type 1, "to configure local interface," or 2, "to
configure remote interface," and press <Enter>.
3. At each successive prompt, press <Space> to cycle through the options and press <Enter> to
select an option or type a number to select values for the parameters, according to the information 
in Table 13. 
4. To set up LOS Detection or Redundancy, type
3
or
4
and follow the prompts on the screen.
Note: LOS detection differs by application. For a 530 or 422 (with controls) interface, LOS uses
RTS. For a T22, D22, and T88 interface, LOS uses SCTE. For T1/E1, LOS tracks 175 
consecutive zeros. TTL/BNC interfaces do not support LOS. 
Model 2370 User Manual