4.15 System

Alarms

The System Alarms screen reports alarms and faults on the local 2370 and the remote 2370. See
Figure 20 and Table 19. To view current alarm status, follow these steps:

1. From the Main Menu, type 5, Alarms, and press <Enter>. The System Alarms report appears.

2. To return to the Main Menu, press <Esc>.

------------------------------SYSTEM ALARMS-------------------------------

Local Remote


Modem Redundancy Status N/A N/A
Configuration Errors No No
Fiber Loss of Signal No No
Electrical Loss of Signal No No
SQL Rx OK OK
Chassis Management N/A N/A
Alarm Relay Inputs N/A N/A
Power Supply Primary OK OK
Power Supply Secondary N/A N/A
Fan N/A N/A
Power-On Self Test OK OK

Figure 20. System Alarms Screen

Table 19. System Alarms Definitions

Item Definition

Modem Redundancy
Status

Reports if redundancy is Active, Inactive, or turned off (N/A)

Configuration Errors

Check that the local and remote modems have compatible set ups,
including software version

Fiber Loss of Signal

Checks if optical loss of signal errors

Electrical Loss of Signal When LOS detection is On, checks if electrical loss of signal occurs
SQL Rx

Checks if squelch occurs

Chassis Management

Reports OK if 2370 is in UCS 1000 with DMM or N/A if 2370 is in
1040, 1050, or UCS 1001

Alarm Relay Inputs

Reports Loss if CLS occurs or OK if signal is good; UCS 1001, only

Power Supply Primary

Reports function of main power supply

Power Supply Secondary Reports function of second power supply
Fan

Reports fan failure

Power-On Self Test

Reports OK or faulty hardware or software