9145E Ethernet Network Interface Device User’s Manual

Installation

Mounting Options

20

3.3.2 Wall Mounting

CAUTION:Fasteners used for wall mounting of the 9145E are required to

withstand a force of three times the weight of the 9145E, applied in
any direction. Failure to meet these requirements could result in
damage to the equipment.

The bottom panel of the 9145E is designed with keyhole cutouts to accommodate wall mounting.

A template is provided with the Quick-Start Guide so that the installer can precisely fasten mount-

ing screws onto a wall. Two number 8 screws and wall anchors, which are not provided by

Canoga Perkins, are used for wall mounting. The keyholes are designed so that the 9145E unit

can be mounted in three positions: with front panel facing the floor, to the right or to the left (see

Figure 3-8).

Figure 3-8.

Wall Mounting Cutout Locations

Assure that there is enough unobstructed space around the perimeter of the 9145E to allow for

adequate airflow and servicing. Install the 9145E on a wall as follows:

1. Tape the template (see Figure 3-9) to the wall, ensuring that the edge of the template cor-

responding to the direction you wish to mount the unit is parallel to the floor and ceiling.

2. Drill a hole through the center of each hole position marker on the template.
3. Remove the template from the wall
4. Install a screw anchor in each drilled hole, then install a #8 screw into each anchor. Leave

the screws protruding from the wall approximately 1/8”.

5. Place the keyholes of the 9145E over the screws, then slide the unit down to lock it into

position on the screws.