2 horizontal flat surface mounting, 4 installing the sfp module, Horizontal flat surface mounting – CANOGA PERKINS 9145ELB Network Interface Device Hardware User Manual
Page 29: Installing the sfp module, Figure 3-2

Installation
9145ELB NID Hardware User’s Manual
Installing the SFP Module
15
Figure 3-2 Installing the Rack Mount Kit
3.3.2 Horizontal Flat Surface Mounting
The 9145ELB requires at least one inch of unobstructed space around the perimeter for
ventilation. Canoga Perkins recommends a space of 3 to 5 inches be left unobstructed to allow
for SFP module access, cable access, and power connections.
To install the 9145ELB on a flat surface, place the 9145ELB on a secure flat surface such as a
table, a shelf, or a desk within reach of the power and fiber optic cables.
Connect the power and fiber optic cables to the 9145ELB as required.
3.4 Installing the SFP Module
Follow these steps to install the SFP module:
1. Determine which SFP Module(s) is/are required for the user and Network Ports by
referencing the SFP Product Data Sheet.
2. Insert a module into each available port and push firmly to seat the module (
).
3. Raise the latch to lock the module in place.