Message codes, Care, Warranty – Leica Geosystems Leica DISTO D810 touch - Manual User Manual

Page 39: 38 en message codes

Advertising
background image

Leica DISTO

TM

D810 touch 799093a

38

EN

Message Codes

If the message Error does not disappear
after switching on the device repeatedly,
contact the dealer.
If the message InFo appears with a number,
press the Clear button and observe the
following instructions:

Care

Clean the device with a damp, soft cloth.

Never immerse the device in water.

Never use aggressive cleaning agents or
solvents.

Warranty

Lifetime Manufacturer's Warranty
Warranty coverage for the entire usage time
of the product according to Leica Geosys-
tems International Limited Warranty. Free of
charge repair or replacement for all products
that suffer defects as a result of faults in mate-
rials or manufacturing, for the entire life of
the product.
3 Years No Cost
Guaranteed service should the product
become defective and require servicing
under normal conditions of use, as described
in the user manual, at no additional charge.

To receive the "3 years no cost" period, the
product must be registered at www.leica-
geosystems.com/registration within 8 weeks
of the purchase date. If the product is not
registered, a "2 years no cost" period applies.

Functions

Distance measuring

yes

Min/Max measuring

yes

Permanent measuring

yes

Stake-out

yes

Addition/Subtraction

yes

Area

yes

Triangle area

yes

Volume

yes

Trapezium

yes

Painter function (area with partial
measurem.)

yes

Pythagoras

2-point, 3-point

Smart Horizontal Mode /
Indirect height

yes

Height-profile measurement

yes

Level

yes

Sloped objects

yes

Height tracking

yes

Memory

yes

Beep

yes

Illuminated colour display

yes

Multifunctional endpiece

yes

Pointfinder (Viewscreen)

4x zoom, OV

Bluetooth

®

Smart

yes

Personalized Favorites

yes

Timer

yes

Long Range Mode

yes

Calculator

yes

Photo/Screenshot

yes

Compass

yes

Gallery with USB download

yes

Diameter

yes

Width

yes

Area from Photo

yes

No.

Cause

Correction

156

Transverse tilt greater
than 10°

Hold the instrument
without any transverse tilt.

162

Calibration mistake

Make sure, the device is
placed on a absolutely
horizontal and flat surface.
Repeat the calibration
procedure. If the mistake
still occurs, contact your
dealer.

204

Calculation error

Perform measurement
again.

240

Data transfer error

Repeat procedure.

252

Temperature too high Let device cool down.

253

Temperature too low Warm device up.

255

Received signal too
weak, measuring time
too long

Change target surface
(e.g. white paper).

256

Received signal too
high

Change target surface
(e.g. white paper).

257

Too much back-
ground light

Shadow target area.

258

Measurement outside
of measuring range

Correct range.

260

Laser beam inter-
rupted

Repeat measurement.

Advertising