Timer (self-triggering)

Press this button to set a 5-second time delay.

or

Press and hold down this button until the

desired time delay is reached (max. 60 seconds).

Once the key is released the remaining seconds until
measurement (e.g. 59, 58, 57...) are displayed in a
countdown. The last 5 seconds are counted down
with a beep. After the last beep the measurement is
taken and the value is displayed.

)

The timer can be used for all measurements.

Appendix

Message codes

All message codes are displayed with either

or

"Error". The following errors can be corrected:

Cause

Remedy

156

Transverse tilt
greater than 10°

Hold the instrument
without any transverse
tilt

160

Main tilt direction,
angle too high
(> 45°)

Measure angle up to
max. ± 45°

204

Calculation error

Repeat procedure

252

Temperature too
high

Cool down instrument

253

Temperature too
low

Warm up instrument

255

Receiver signal too
weak, measurement
time too long,
distance > 100 m

Use target plate

256

Received signal too
strong

Target too reflective
(use target plate)

257

Wrong measure-
ment, background
brightness too high

Darken target (measure
in different lighting
conditions)

260

Laser beam inter-
rupted

Repeat measurement

Error

Cause

Remedy

Error

Hardware error

Switch on/off the
device several times. If
the symbol still
appears, then your
instrument is defective.
Please call your dealer
for assistance.

Cause

Remedy