Rs 485 connection, Note, Rs485 termination switch setting – Panasonic WV-CPR650 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Type of
coaxial cable

RG-59/U

(3C-2V)

RG^eu

(5C-2V)

RG-11/U

(7C-2V)

RG-15/U

{10C-2V)

Recommended
maximum
cable length

(m)

250

500

600

800

(fl)

825

1 650

1980

2 640

< Bottom View>

3. Wiring precautions:

• Do not bend the coaxial cable into a curve whose

radius is smaller than 10 times the cable’s diame­
ter.

• Never staple the cable even if with circular sta­

ples. Impedance mismatching will occur.

• Never crush or pinch the cable.

Ah of the above will change the impedance of the

cable and cause poor picture quality.

RS485 Termination Switch Setting

If the daisy chain connection is used, the termination

switch setting is required. Follow the procedures as

below.

The termination switch is set to ON at the factory.

1. Remove the mount adapter and cover by remov­

ing four screws.

2, Set the termination switch on the RS485 board to

ON for the furthermost camera from the

RS232C/R3485 converter and OFF for the other

cameras.

RS 485 Connection

T{A)

T{B)

GND

Note:
Use the cable that is described below for RS485
site communication.

• shielded, two twisted pairs cable
• Low impedance
• Wire gauge size is thicker than AWG#22

{0.33mm=)

-9-