Table 2, Notes – Panasonic WJ-SQ308 User Manual

Page 11

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 2

Signal Output Condition

Without VCR

With VCR

Sequential switching Time

C-A: The sequential switcher's timing can

be adjusted using the Time Control (1)

when the Internat/External Selection

Switch (2) is set to the I NT position.

C-B/C:The signals are synchronized with C-A

when the Time Internal/External Selec­
tion Switch (2) on WJ-SQ308S (C-B
and C-C) are set to the EXT position.

Set Internal/External (C-A) Selection

switch to I NT position.

All of the WJ-SQ308 is can be sequenced

with the timing pulse from VCR;

Note: Be sure to set the Time Inter­

nal/External Selection Switch (2) to the
EXT position

Normal Sequence mode

1. Alarm/Spot Output Connec­

tor

2. Atarm/Sequential Output

Connector

The signal from all of the WJ-SQ308s are
output sequentially with the switching time

from the C-A Unit.

All of the WJ-SQ308S are sequenced with the

timing pulse from the VCR.

Spot mode

1. Alarm/Spot Output Connec­

tor

2. Atarm/Sequential Output
Connector

1. The WJ-SQ308 in the spot mode supplies

the selected video signal to the Alarm

Spot Output Connector (11). All Other WJ-

SQ308s go to sequencing with the timing

set by the WJ-SQ308 (C-A).

2. The signal from all of the WJ-SQ308S are

output sequentially with the switching time

set by the WJ-SQ308 (C-A).

1. The WJ-SQ308 In the spot mode supplies

the selected video signal to the Alarm
Spot Output Connector (11). All other WJ-
SQ308s go to sequencing with the switch­

ing time set by the timing pulse from VCR.

2. The signal from all of the WJ-SQ308s are

switched with the switching time by the

timing pulse from VCR

Alarm mode (1 input)

1. Alarm/Spot Output Connec­

tor

2. Alarm/Sequence Output

Connector

1. The alarmed video signal is output from

the Alarm Spot Output Connector (11),

Other WJ-SQ308s go to sequence. (The
spot operation is available for 1-ch - 8-ch)

2. The alarmed video signal is output from

the Alarm Spot Output connector (11). All
Other WJ-SQ308s go on the sequence.

1. The WJ-SQ308 (D) supplied with the

alarm signal is switched to the alarm pic­

ture.

All

other

WJ-SQ308S

go

to

sequence. (The spot operation is available

for 1-ch - 8-ch)

2. The WJ-SQ308 (D-B) supplied with the

alarm signal is switched to the alarm pic­
ture. All Other WJ-SQ308S go to sequenc­

ing with the switching time set by the tim­

ing pulse from VCR.

Alarm mode (multiple input)

In case of alarm input to the (C-

B or D-B)

1. Alarm/Spot Output Connec­

tor

2. Alarm/Sequential Output

Connector

The alarm timing of the WJ-SQ308 (C-C).
supplied

the alarm input

signal,

is

sequenced with the timing of WJ-SQ308
All Other WJ-SQ308s go for sequence.

(The spot or bypass operation is avail­
able for 1-ch - 8-ch)

The alarm timing of the WJ-SQ308 (C-B),

supplied

the alarm input

signal,

is

sequenced with the timing of Master WJ-
SQ308 All other WJ-SQ308s go to

sequence.

(The bypass operation is

available for 1-ch - 8-ch)

1. The alarm timing of, the WJ-SQ308 (D-B)

supplied

the

alarm

input

signal,

is

sequenced with the timing pulse from

VCR. All Other

\A/J-SQ308s go

to

sequence. (The spot or bypass opera­
tion is available for 1-ch - 8-ch)

2. The alarm timing of, the WJ-SQ308 (D-B)

supplied with the alarm input signal, is

sequenced with the timing pulse from

VCR. All Other

WJ-SQ308S

go

to

sequence.

(The

bypass

operation

is

available for 1-ch - 8-ch)

Notes:
The switching interval of VCR and Camera should be 0.3 seconds or more.

Each screen of video monitors are not same with the camera screen.

A Time Lapes VTR may be connected to each WJ-SQ308.

-

9

-