Mmim – Panasonic QUICKDRAW MC-V5340 User Manual

Page 15

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

A

mmim

Electrical Shock or Personal Injury Hazard

Disconnect the electrical supply before servicing or cleaning the unit. Failure to do

so could result in electrical shock or personal injury from cleaner suddenly starting

1. When to replace the agitator assembly

The agitator assembly should be replaced when the

brushes are worn Brushes should be checked by
holding a card across the bottom plate (see illustration)

If the bristles on the agitator assembly do not touch the

card you should replace the agitator assembly for best
cleaning results

2 How to replace the agitator assembly.

Place the vacuum cleaner handle in the low position (See the Handle Adjustments section )
Remove the lower plate as outlined in the Removing/lnstalling the Lower Plate section After

the lower plate is removed, carefully lift up the agitator assembly until it clears both sides of
the nozzle housing While holding the agitator assembly up, remove the belt

CAUTION The two end caps may come off along with the two washers as you lift the
agitator assembly out Do not lose the two small washers Look at the exploded view of
the agitator assembly below for correct assembly of parts

3 To replace the agitator assembly

Place the belt over the belt pulley on the agitator unit (NOTE There is a place for the belt

to fit on one end of the agitator assembly only) Replace both washers and end caps (see

Illustration below for correct assembly) After assembling the belt, washers and end caps
place the agitator assembly back into the nozzle housing by aligning each end cap

After completing the assembly, rotate the brush, turning it by hand to assure that

it rotates smoothly and the part is assembled correctly

Replace the lower plate as outlined in the Removing/lnstalling the Lower Plate section

-

15

-