KX-P1150

The Carriage motor is driven by the four signals from CRA, CRB, CRNA and CRNB, and is driven by 1-2 phase
driving system.

The time interval is determined by the CPU's interval counter clock as generated from the CPU's clock.

This circuit is a chopper drive circuit for fixing the amount of the current through the motor during stepping and

has two threshold voltages

(V

sh

, V

sl

).

IC207 compares the voltage drop across R212 (R213) which is in

proportion to the current through the motor. For example, when the voltage drop across R212 (R213) is larger

than

V

sh

,

IC207 is turned off and Q202 (Q203) is turned off, then Q200 (Q201) is turned off. At the same time, the

current through the motor decreases, because the voltage drop across R212 (R213) decreases. When this
voltage drop is smaller than

V

sl

,

IC207 is turned on, and the current through the motor increases.

The amount of current through the motor is fixed during stepping by repeating this process.

These threshold voltage

(V

sh

, V

sl

)

are able to be changed by IC205

pin

95 H or L signal duty Ratio according to

8.2.4 Carriage Motor Drive Biock

Timing Chart

CRA

CRB

CRNA

Carriage Motor Coil Resistance Value

Pin No.

(CN202)

Resistance Value

6-5

9.5 ± 0.7 ohms

4-5

9.5 ± 0.7 ohms

1-2

9.5 ± 0.7 ohms

3-2

9.5 ± 0.7 ohms

CRNB