Panasonic CSXC181KP User Manual
Page 19
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

r
(
2^
Recommended about once every 3 months.
1
Remove the air filters.
2
Remove the air purifying
filters.
3
Remove the filters from
the filter frame.
Filters
Air filter
Air purifying filter
<Note>
Sample colour
If air purifying filters turn the same colour as the sample colour attached to
the indoor unit within a three month period, replace the filters.
Re-insert the filters correctly at the left and right with the side marked
[FRONT] facing forward.
Dusty filters cannot be re-used, even if they are cleaned and washed.
Purchase replacement filters from your air conditioner dealer.
Part number for air purifying filters: CZ-SF5N
[Ml oMs]® ©0F
1
Operate the air condi
tioner for 2 to 3 hours.
■ Type of operation: Fan.
2
For air conditioners with a
power plug, stop opera
tion by remote control and
pull out the power plug.
Note:
If the unit is not off by
remote control, the unit
will operate when you
plug in (because
^
of Auto-restart
®
Control is provided).
3
Remove the batteries
from the remote control.
In order to dry out the
internal mechanisms
HE
2
Operate for 15 min
utes.
If the difference in tem
perature between the air
outlet vent and air in
take vent is 8°C or more
when cooling, the unit is
normal.
Are the air outlet
vents and air intake
vents obstructed?
Is the drain hose
cracked or crushed?
Are
the
remote
control batteries in
good condition?