Technical data, El ectrical connection, No rmal maintenance – STIEBEL ELTRON Tempra 36 User Manual

Page 7: Putting th e water heater into o peration

Advertising
background image

– 7 –

English

3 / (100)

7

8

26_02_02_0607

Water connections

NPT

3/4“

Weight

lbs. / kg

14.3 / 6.5

17.6 / 8.0

17.6 / 8.0

24.7 / 11.2

17.6 / 8.0

24.7 / 11.2

24.7 / 11.2

Dimensions height

inch / mm

14

4

/

8

/ 367

depth

4

5

/

8

/ 116

width

14

5

/

8

/ 372

14

5

/

8

/ 372

14

5

/

8

/ 372

21

6

/

8

/ 552

14

5

/

8

/ 372

21

6

/

8

/ 552

21

6

/

8

/ 552

Nominal water volume

GAL / l

0.13 / 0.5

0.26 / 1.0

0.26 / 1.0

0.39 / 1.5

0.26 / 1.0

0.39 / 1.5

0.39 / 1.5

Required wire size

AWG COPPER 6

6

2 x 8

2 x 8

2 x 8

2 x 8

3 x 8

3 x 8

2 x 6

2 x 6

3 x 8

3 x 8

3 x 6

3 x 6

Min. water flow
to activate unit

GPM / l/min

0.29 / 1.1

0.58 / 2.2

0.58 / 2.2

0.87 / 3.3

0.58 / 2.2

0.87 / 3.3

0.87 / 3.3

Tested to pressure

PSI / bar

300 / 20

Technical Data

Min. required
circuit breaker size

A 60

60

2 x 40 2 x 40 2 x 50 2 x 50 3 x 40 3 x 40 2 x 60 2 x 60 3 x 50 3 x 50 3 x 60 3 x 60

El

ectrical connection

WARNING: BEFORE BEGINNING
ANY WORK ON THE ELECTRIC

INSTALLATION, BE SURE THAT MAIN
BREAKER PANEL SWITCHES ARE “OFF“
TO AVOID ANY DANGER OF ELECTRIC
SHOCK. ALL MOUNTING AND PLUM-
BING MUST BE COMPLETED BEFORE
PROCEEDING WITH ELECTRICAL
HOOK-UP. WHERE REQUIRED BY LO-
CAL, STATE OR NATIONAL ELECTRI-
CAL CODES THE CIRCUITS SHOULD
BE EQUIPPED WITH A “GROUND FAULT
INTERRUPTER“.

1. All electrical work must comply with natio-

nal and applicable state and local electrical
codes.

2. The TEMPRA should be connected to pro-

perly grounded dedicated branch circuits
of proper voltage rating. Ground must be
brought to the “Ground“ at the circuit brea-
ker panel.

G

A

TEMPRA 12 can be conected to a

single circuit. Use a supply cable protected
by a double pole breaker (see

2

).

The TEMPRA 15 to TEMPRA 36 must have

multiple power sources.

H

A

TEMPRA 15, 20 or a TEMPRA 24

require two independant circuits. Use two
supply cables protected by two seperate
double pole breakers (see

2

).

I

A

TEMPRA 22, 29 or a TEMPRA 36

require three independant circuits. Use
three supply cables protected by three se-
perate double pole breakers (see

2

).

Please refer to the technical data table for

the correct wire and circuit breaker size. In

all cases, make sure that the unit is properly
grounded.

3. Cut the electrical connection cable to

length and strip.

perature in degree Celsius. There is a con-
version table on the front cover that helps
to convert from degree Celsius to degree
Fahrenheit.

3. Turn on hot water and wait twenty seconds

until temperature has stabilized.

4. Check the water temperature with your

hand and make sure that it does not feel
too hot. Reduce if necessary.

5. Explain to the user how the unit works and

familiarise him or her with its use.

Advise the user about possible hazards (hot

water temperature up to 125 °F / 52 °C).
Hand over these instructions, to be kept
for future reference.

No

rmal maintenance

STIEBEL ELTRON TEMPRA tankless water he-
aters are designed for a very long service life.
Actual life expectancy will vary with water
quality and use. The unit itself does not re-
quire any regular maintenance. However, to
ensure consistent water flow, it is recommen-
ded to periodically remove scale and dirt that
may build up at the aerator of the faucet(s) or

in the shower head.

E

Also, the TEMPRA

has a built in filter screen

3

that should be

cleaned from time to time. In order to do
this, turn off the cold water supply at the iso-
lating valve

1

and remove the cap

2

of the

filter screen. Clean screen and put the screen
and cap back into their original position.

OTHER THAN THE FILTER SCREEN,
THE

TEMPRA DOES NOT CON-

TAIN ANY PARTS SERVICEABLE BY THE
LAY PERSON. IN CASE OF MALFUNC-
TION PLEASE CONTACT A LICENSED
PLUMBER OR ELECTRICIAN.

Model

TEMPRA 12 TEMPRA 15 TEMPRA 20 TEMPRA 22 TEMPRA 24 TEMPRA 29 TEMPRA 36

Working pressure

PSI / bar

max. 150 / 10

Max. amp. load

A 44

50

2 x 26 2 x 30 2 x 35 2 x 40 3 x 26 3 x 30 2 x 44 2 x 50 3 x 35 3 x 40 3 x 44 3 x 50

Wattage kW

9

12 10.8

14.4 14.4 19.2 16.2 21.6 18 24 21.6

28.8 27 36

Voltage V

208

240 208 240 208 240 208 240 208 240 208 240 208 240

Phase

1 1 1 1 1 1 1

– Suitable for supply with water up to 107.6 °F / 42 °C
– Tankless water heaters are considered a non-continuous load
– Conductors should be sized to maintain a voltage drop of less than 3 % under load

4. The wire must be fed through the knock-

outs located between the hot and cold
water connections

G - I

1

. The “live“

wires must be connected to the slots on
the terminal block marked L and L. The
ground wire must be connected to slot
marked with the ground symbol (see

3

).

5. Reinstall the cover with screws.

WARNING: AS WITH ANY ELEC-
TRIC APPLIANCE, FAILURE TO

ELECTRICALLY GROUND UNIT MAY RE-
SULT IN SERIOUS INJURY OR DEATH.

Putting th

e water heater

into o

peration

WARNING: OPEN HOT WATER
FAUCET FOR A FEW MINUTES

UNTIL WATER FLOW IS CONTINUOUS
AND ALL AIR IS PURGED FROM WATER
PIPES. THE UNIT’S COVER MUST BE
INSTALLED BEFORE THE CIRCUIT BREA-
KERS ARE TURNED ON.

1. Turn on circuit breakers to bring electrical

power to the unit.

2. Adjust the water temperature to the desi-

red level using the knob on the front cover
of the unit. The TEMPRA displays the tem-

Advertising
This manual is related to the following products: