Spare parts, Troubleshooting – STIEBEL ELTRON Tempra 36 User Manual

Page 8

Advertising
background image

– 8 –

J

1

2

3

4

5

6

7

8

3

TEMPRA 22, 29 and 36 only

256126

/1

b

256126

/1

b

256126

/1

b

256126

/1

b

256126

/1

b

256126

/1

b

8834.03

8833.01

No. Spare part

Model TEMPRA 12 TEMPRA 15 TEMPRA 20 TEMPRA 22 TEMPRA 24 TEMPRA 29 TEMPRA 36

1 Heating system

26 65 84

26 90 25

24 91 58

26 90 25

26 65 84

24 91 58

26 65 84

2 Electronic control device: Master

26 47 17

3 Electronic control device: Slave

26 47 18

4 Safety thermal cut out

26 65 83

17 03 05

17 03 05

17 03 05

26 65 83

17 03 05

26 65 83

5 Flow sensor

26 65 85

6 Cold water connection

26 65 86

26 65 87

26 65 87

26 65 88

26 65 87

26 65 88

26 65 88

7 Warm water connection

26 65 90

26 65 91

26 65 91

24 91 68

26 65 91

24 91 68

24 91 68

8 Temperature adjustment knob

16 35 73

Spare parts

J

Troubleshooting

If you are not able to resolve a problem please contact us toll free at 800-582-8423 before removing the unit from the wall.
STIEBEL ELTRON is happy to provide technical assistance. In most instances, we can resolve the problem over the phone.

Symptom Possible

Cause

Solution

No hot water

Water not hot enough

LED displays one of the following fault codes:
91, 92, 93, 94, 95, 96, 97

– circuit breakers off
– safety thermal cut-out tripped

– not enough flow rate to activate unit

– water flow rate too high

– voltage too low

– problem with electronic control module

– turn circuit breakers on
– reset thermal cut-out

– clean filter screen at unit
– clean faucet aerator or shower head

– reduce water flow rate until light on front

cover stops blinking

– supply correct voltage to unit

– contact STIEBEL ELTRON.

Advertising