Damper stop installation, Installation instructions – Vermont Casting VL24 User Manual

Page 8

Advertising
background image

8

20002538

Damper Stop Installation

When installing a decorative gas appliance in a fire-
place, some local codes require a damper stop be
added so the damper will not close completely. The
CFM Corporation damper stop is designed so the
damper can be locked in the closed position, and still
allow a vent for the pilot gasses.
This damper stop is designed to work on all CFM Cor-
poration BR, BC, TF, TL, SR and SC series fireplaces.

Installation Instructions

Open damper. The damper must be open to attach the
damper stop.
Locate the damper locking bracket. From inside the fire-
place locate the damper locking bracket on the left side
of combustion dome. (Fig. 4)
Align the two slots on either side of the cutout on the
damper stop with the two small holes on the angled
portion of the damper locking bracket. Attach the
damper stop with the screws provided. (Fig. 5)
NOTE: Some of the early units may not have the holes
in the end of the damper locking bracket. If this is the
case use the damper stop as a template to drill two (2)
1/8” holes in the damper locking bracket to mount the
damper stop.

DP100

Damper locking bracket

3/19/99 djt

Damper Locking Bracket

Fig. 4 Locate damper locking bracket.

DP100

DP101

Damper stop

3/19/99 djt

Damper Locking Bracket

Attachment Screws (2)

Damper Stop

DP101

Fig. 5 Attach damper stop.

Advertising