Switch must be in the r – Aviom A-16R/A-16CS User Manual

Page 55

Advertising
background image

46

A-16R P

eRsonAl

M

ixeR

And

A-16Cs C

ontRol

s

uRfACe

u

seR

G

uide

For example, if you have just loaded Preset 7 (by pressing the R

ecall

button

followed by the number 7 button), pressing the right pedal once will move

to Preset 8. Pressing the left pedal will move down one, returning you to

Preset 7. Another press of the left pedal loads Preset 6, and so on. Changes

are reflected on the A‑16CS and its connected A‑16R host.

As with other operations involving the A‑16CS, the R

emote

/l

ocal

switch must

be in the R

emote

position in order for the footswitch to be functional. When a

Preset is selected via the footswitch, the corresponding numbered button’s

LED on the front panel of the A‑16R will flash to indicate that the Preset has

been loaded.

The Footswitch jack uses a TRS connection, designed for dual foot pedals.

However, you can substitute a single footswitch (one that has only a tip‑

sleeve connection) if necessary. The Presets will move up only, and will wrap

around from Preset 16 to Preset 1 at the end of the Preset list as described

previously.

The footswitch can be either a normally open or normally closed type. The

pedal is scanned by the system software to determine which type it is, and

to determine what the “up” state of the switch is. The foot pedal should be

connected when the system is powered up. If you change pedals while the

system is in use, you may need to power cycle the unit if the type of pedal is

different.