F

irmwAre

u

PdAte

Firmware Update

The Pro64 firmware can be updated in the field using a PC and the Pro64

Update Tool. Modules can be updated over A‑Net, while part of an active

audio network, or in local mode where no other modules are connected at

the time the update is being performed (such as may be required for a bench

configuration when setting up modules prior to installation).

Updating a module requires the Aviom Pro64 Update Tool application, a PC

host computer with RS‑232 connection capability, a null modem DB9 cable,

and the firmware update file for the particular Pro64 device being updated.

Refer to the Aviom website for information about the availability of the latest

firmware upgrades and feature updates.

Update Connections

To update modules via A‑Net, a host computer is connected to the network’s

Control Master via the RS‑232 port in the Virtual Data Cable section of the

rear panel. Individual modules are then selected and updated from within

the Pro64 Update Tool. Updates can be applied to the Control Master or a

slave device.

To update via A‑Net, make sure that no RS‑232 or MIDI VDC resources are

configured on the Control Master. (Refer to the Virtual Data Cable information

page 33.) Then, enter Managed Mode by pressing the

M

anagEd

button on the

Control Master.

To update modules locally, the computer is connected directly to the module

being updated, via the RS‑232 port as described above. The Pro64 Update

Tool application must also be set to its local update mode. (See the Pro64

Update Tool Help file for more information.)

Baud rates for data transfer must be set the same on the Pro64 device and

PC host running the Pro64 Update Tool. Refer to the VDC RS‑232 baud rate

info (page 60) to learn how to set the baud rate parameters. On the Pro64

module, RS‑232 must be configured for eight data bits, no parity, and one

stop bit. Also, refer to the firmware update instructions that come with the

Pro64 update application for additional information on setting up the PC

host.

Firmware Update - Local

Function 15 enables a Pro64 module to receive new firmware from a host PC

connected to the RS‑232 port on the module’s rear panel. Updates can be

applied to a Pro64 module set to be a Control Master or slave device.