Switching Characteristics

Over the Operating Range

[20, 21]

Cypress

Parameter

Consortium

Parameter

Description

250 MHz

200 MHz

167 MHz

Unit

Min

Max

Min

Max

Min

Max

t

POWER

V

DD

(Typical) to the First Access

[22]

1

1

1

ms

t

CYC

t

KHKH

K Clock and C Clock Cycle Time

4.0

8.4

5.0

8.4

6.0

8.4

ns

t

KH

t

KHKL

Input Clock (K/K and C/C) HIGH

1.6

2.0

2.4

ns

t

KL

t

KLKH

Input Clock (K/K and C/C) LOW

1.6

2.0

2.4

ns

t

KHKH

t

KHKH

K Clock Rise to K Clock Rise and C to C Rise
(rising edge to rising edge)

1.8

2.2

2.7

ns

t

KHCH

t

KHCH

K/K Clock Rise to C/C Clock Rise (rising edge to rising edge)

0

1.8

0

2.2

0

2.7

ns

Setup Times

t

SA

t

AVKH

Address Setup to K Clock Rise

0.35

0.4

0.5

ns

t

SC

t

IVKH

Control Setup to K Clock Rise (RPS, WPS)

0.35

0.4

0.5

ns

t

SCDDR

t

IVKH

DDR Control Setup to Clock (K/K) Rise
(BWS

0

, BWS

1

, BWS

3

, BWS

4

)

0.35

0.4

0.5

ns

t

SD

[23]

t

DVKH

D

[X:0]

Setup to Clock (K/K) Rise

0.35

0.4

0.5

ns

Hold Times

t

HA

t

KHAX

Address Hold after K Clock Rise

0.35

0.4

0.5

ns

t

HC

t

KHIX

Control Hold after K Clock Rise (RPS, WPS)

0.35

0.4

0.5

ns

t

HCDDR

t

KHIX

DDR Control Hold after Clock (K/K) Rise
(BWS

0

, BWS

1

, BWS

3

, BWS

4

)

0.35

0.4

0.5

ns

t

HD

t

KHDX

D

[X:0]

Hold after Clock (K/K) Rise

0.35

0.4

0.5

ns

Output Times

t

CO

t

CHQV

C/C Clock Rise (or K/K in Single Clock Mode) to Data Valid

0.45

0.45

0.50

ns

t

DOH

t

CHQX

Data Output Hold after Output C/C Clock Rise
(Active to Active)

–0.45

–0.45

–0.50

ns

t

CCQO

t

CHCQV

C/C Clock Rise to Echo Clock Valid

0.45

0.45

0.50

ns

t

CQOH

t

CHCQX

Echo Clock Hold after C/C Clock Rise

–0.45

–0.45

–0.50

ns

t

CQD

t

CQHQV

Echo Clock High to Data Valid

0.30

0.35

0.40

ns

t

CQDOH

t

CQHQX

Echo Clock High to Data Invalid

–0.30

–0.35

–0.40

ns

t

CHZ

t

CHQZ

Clock (C/C) Rise to High-Z (Active to High-Z)

[24, 25]

0.45

0.45

0.50

ns

t

CLZ

t

CHQX1

Clock (C/C) Rise to Low-Z

[24, 25]

–0.45

–0.45

–0.50

ns

DLL Timing

t

KC Var

t

KC Var

Clock Phase Jitter

0.20

0.20

0.20

ns

t

KC lock

t

KC lock

DLL Lock Time (K, C)

1024

1024

1024

Cycles

t

KC Reset

t

KC Reset

K Static to DLL Reset

30

30

30

ns

Notes

21. When a part with a maximum frequency above 167 MHz is operating at a lower clock frequency, it requires the input timing of the frequency range in which it is being

operated and outputs data with the output timings of that frequency range.

22. This part has a voltage regulator internally; t

POWER

is the time that the power is supplied above V

DD

minimum initially before a read or write operation is initiated.

23. For D2 data signal on CY7C1910BV18 device, t

SD

is 0.5 ns for 200 MHz, and 250 MHz frequencies.

24. t

CHZ

, t

CLZ

, are specified with a load capacitance of 5 pF as in part (b) of

AC Test Loads and Waveforms

. Transition is measured ±100 mV from steady state voltage.

25. At any voltage and temperature t

CHZ

is less than t

CLZ

and t

CHZ

less than t

CO

.