4.2 GAIN Adjustment

Requirement: ZERO adjustment carried out.

1. Thread the process material through the measuring and guide rollers, following

the material path symbol on the front of the sensor.

2. Hang a weight that corresponds to e.g. 95% of the tension range from the

process material.

3. Adjust the potentiometer, which you can reach through the GAIN hole in the

housing, with a screwdriver (with a point width of max. 1.9 mm) until the

display of the connected volt meter reads,

for example:

Sensor model TS2 - 200:

Weight 190 g = Display 0.950 V for TS2 standard version

or

Weight 190 g = Display 9.50 V for TS2 version with 10 V output signal.

WARNING: Do not insert the screwdriver at an angle as this may damage
the potentiometer.

4. Check the adjustments with a fresh portion of the process material and repeat

the procedure, if required, as described in Chapters 3.3.1 and 3.3.2.

!