Electrical: engine-stopping safety circuits, Cub cadet commercial z-wing – Cub Cadet Z-Wing User Manual

Page 79

Advertising
background image

Cub Cadet Commercial Z-Wing

75

30.6. To stop the engine without an occurrence of

after-fire, it is necessary to deprive the after-fire
solenoid of power from the charging circuit as
well as from the key switch.

30.7. This is done by grounding-out the charging cir-

cuit through the key switch connection to G ter-
minal.

30.8. Through the M terminal, the magneto finds

ground by its connection to the G terminal with
the key in the OFF position.

31.

ELECTRICAL: ENGINE-STOPPING SAFETY
CIRCUITS

31.1. The object of the engine stopping safety circuits

is to prevent the mower from running if an inher-
ently unsafe condition exists.

31.2. Unsafe conditions that will cause engine shut-

down include:

•

Engine running with the seat unoccupied and the
parking brake released.

•

Engine running with the seat unoccupied and the
cutting deck engaged.

31.3. The seat safety switch is central to the system.

See Figure 31.3.

NOTE: Seat switch plug defaults to closed circuit
if disconnected.

Figure 31.3

Seat safety switch:
normally closed

Plug defaults to closed
circuit if disconnected

31.4. The yellow wire that connects the M terminal on

the key switch to the ignition modules connects
to the seat switch. The paired yellow w/white
trace wires from the second terminal on the seat
switch extend to the Brake switch and the PTO
switch.

31.5. If the seat is empty (contacts closed) a ground

path may be completed through the PTO switch.
See Figure 31.5.

31.6. If the seat is empty (contacts closed) a ground

path may be completed through the brake
switch. See Figure 31.6.

Figure 31.5

S

M B


L G

Battery

A-F
Sol.

PTO Switch: ON

Key Switch:
RUN

Ignition

Module

Seat
Switch:
Empty

Figure 31.6

S

M B


L G

Battery

A-F
Sol.

Key Switch:
RUN

Ignition

Module

Seat
Switch:
Empty

Brake Switch: OFF