10 appendices, Complete initialisation – Doepfer Regelwerk (device no longer available) User Manual

Page 36

Advertising
background image

Doepfer Musikelektronik GmbH

User manual V1.0

REGELWERK V1.2


10 Appendices


10.1 LCD readouts during the
reception of MIDI SysEx data:

If a SysEx Pattern is successfully received by

REGELWERK

without any errors, and is

written into the relevant pattern memory, the
following message appears in the LCD
readout:-

Receive Pat.: xxx


If a SysEx dump has a problem, and

produces an error, this message appears:-

MIDI Receive Error
SysEx Dump

The cause of an error like this can either be a

problem with the actual MIDI dump format, or
too large an amount of data for

REGELWERK

to handle. When sending a SysEx dump,
short pauses should be inserted between the
packets of MIDI information.

Errors are most likely to happen if the

sequencer is running at a high tempo, with
short step times, large numbers of
simultaneous events, and a SysEx dump all
happening at the same time. With further
stress placed on the system by having to
process large amounts of data at the MIDI
Inputs, the internal buffer could sometimes
overflow, and cause errors.

These messages are only temporarily

displayed. As soon as a new event occurs,
the message will be over-written.

FOR CONTROL PURPOSES:

a Preset Dump is sandwiched between two

SysEx strings. The entire first string is
composed of 1035 bytes.

If that's not the case, something's gone

wrong with the dump!

10.2

Complete Initialisation

REGELWERK

can be completely initialised

(hard reset).

This might be necessary or desirable

because..

you want to erase all a previous owner's data

there's been a crash or electrical fault of

some description, and

REGELWERK

contains

some spurious data in its memory which it
can't process.

To perform a hard reset, hold down the Start

button while switching on power to the unit.


The following message appears:-

INIT MENUE! <OK>

FORMAT PRESET RAM

After pressing the OK button (note that in this

mode, unlike others, the LED doesn't blink),
the next message appears:-

Format total RAM

and the entire set of memory locations is erased
and initialised.

This can take quite a few seconds, as each of

the 128 locations is re-set in turn ..

Init Ram 1-128

and then

REGELWERK

returns to its usual

mode of operation.

This process irrevocably deletes all the user

data in the

REGELWERK'

s

memory locations.

It's recommended only for service purposes,
or as a quick way to return

REGELWERK

to

its factory settings. It's vital to remember to
use a MIDI SysEx dump to save all data that
you might regret losing.

Advertising