TRIGGER LEVEL ON

Sets the output level of the trigger on signal, referenced as a percentage of maximum (10.6v for outputs

13 ~ 24). So 50% would generate a 5.3V trigger. For V-Trig applications (positive gate like Doepfer A-100
and most others) use high percentage for Trigger Level on, and for S-Trig applications (like Moog) use a
Trigger On Level of 0%.

TRIGGER LEVEL OFF

Sets the output level of the trigger off signal, referenced as a percentage of maximum (10.6v for outputs

13 ~ 24). So 50% would generate a 5.3V trigger. For V-Trig applications (positive gate like Doepfer A-100
and most others) use a Trigger Level off of 0%, and for S-Trig applications (like Moog) use a Trigger Off
Level of 100% (or suitable high level).

GLOBAL SYNC PARAMETER

The Global Sync Parameter is where control over the system clock and sync parameters are set.

CLOCK TIME

This sets the MIDI clock division ratio, a normal setting of 1 passes the MIDI clock unprocessed,

whilst a setting of 3, divides the clock by 3 (1/96 becomes 1/32). Range is 1 ~ 255.

Tr i g g e r : O u t p u t 0 1

Le v e l O n

V % : 1 0 0

Tr i g g e r : O u t p u t 0 1

Le v e l O f f

V % : 0 0 0

<- - - - - F>:Ou t p u t 0 1

Gl o b a l S y n c P a r .

Sy n c - C l o c k

Cl o c k T i m e : 0 0 1