Fire By Design VULCAN User Manual

Page 5

Advertising
background image

5






































Acceptable Media for Fire Features




24 volts

from

Transformer

Drain

Line

Gas

Line

Electrical

Conduit

Illustration of Properly Installed Vulcan Fire Module

1” above ring

Arrow

WARNING

Do not use any other material as filler/topping media inside fire features other than those listed below.

Using improper media inside a fire feature could result in damage to property or

injury to persons nearby due to media ‘popping’ or ‘exploding’ due to heat

Vulcan

Fire

Module

The illustration above shows the Vulcan Fire Module as it would look after installation is complete inside a small bowl.
1. First step is to apply pipe dope to the gas riser.
2. Next thread the Vulcan Fire Module onto the gas line ensuring it is tight to prevent gas leaks.
3. Then attach the two wires from the Vulcan Fire Module to the two wires coming from the 24 volt transformer.
4. Add Acceptable Fire Feature media as desired. (See next page for a list of Acceptable Media).
5. Installation Complete.

Installation

Note: Installation should be done by a qualified service technician that is locally licensed.