4| Compressor assembly

Fig. 17

Fig. 18

Valve spindle seal

Release

Tighten

Pipe connection

Pipe connection

4.7 Operating mode of the lockable service connections

Fig. 19

Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.

Fig. 20

Opening the service connection
Spindle: Turn ½ - 1 turn clockwise.
—> Service connection opened / shut-off valve opened.

Connection
blocked

Spindle

Spindle

Connection
open

Compressor

Compressor

Service connec-
tion closed

Service connec-
tion opened

4.6 Operating the shut-off valves

Before opening or closing the shut-off valve, release the valve spindle seal by approx. ¼ of a turn

counter-clockwise.

After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.