HI HLPS SERIES LOAD POINT ASSEMBLY
Page 8
Round Vessel with 3 
Load Point 
Assemblies - Angle 
Config. #2
FIG. 8: ANGLE FOR ALL LOAD CELLS IN ROUND
CONFIGURATION
NOTE:
Load Cells can be oriented with cables pointed either 
in or out. For three load point systems, the mounting 
locations should be spaced120 degrees apart. For 
four load point systems the mounting locations should 
be spaced 90 degrees apart.
Square Hopper with 
3 Load Point 
Assemblies - Even 
Load Distribution
FIG. 9: ANGLE FOR FIXED AND BUMPER LOAD
CELLS IN SQUARE CONFIGURATION
F
S
B
O
                                    Advertising
                    
                        
                    
                            
                            