Time and date setup (model 350), Isplay, Apture – Holtgreven GSE-355 I.S. User Manual

Page 93: Tility

Advertising
background image

84

Command

ASCII

HEX

Description

Piece Wt.

Entry

%9

B9h

Allows a piece weight to be entered serially. For example, 0.10%9 will
enter a piece weight of 0.10.

Print

W<CR>

or

P<CR>

57h, 0Dh

Initiates print function. Print restrictions (P200-P212) will be adhered to.
Requires both hex values, 57h followed by 0Dh.

Zero

Z<CR>

5Ah, 0Dh

Initiates zero function. Zero restrictions (118) will be adhered to. Requires
both hex values, 5Ah followed by 0Dh.


<CR> is a carriage return, decimal value 013, hex value 0Dh.

D

ISPLAY

C

APTURE

U

TILITY

The Display Capture Utility sends the current display information out of the comm port when the extended ASCII
character represented by decimal 149 (hex: 95h) is received through the comm port. Entering a decimal 149 from a
computer keyboard can be accomplished by turning on the Num Lock and holding down the ALT key while typing the
desired decimal number on the keyboard keypad (for example, <Alt>149).



The Display Capture Utility must have NTEP disabled in order to function.


E

XAMPLE

#1

The scale is in the weigh mode with the gross weight displayed (for example, 15.00).

Input: The extended ASCII character represented by decimal 149 (hex: 95h) is received through the comm port.

Output: “15.00 lb Gross ” is sent out the comm port.

E

XAMPLE

#2

The scale is in setup at P110 Full Scale.

Input: The extended ASCII character represented by decimal 149 (hex: 95h) is received through the comm port.

Output: “P110 F.S. 100.00 ” is sent out the comm port.

Time and Date Setup (Model 350)

The time and date feature is stored as non-volatile (time/date setting will not be lost when the unit power is
reset). The time/date parameter is available in the first two fixed transmits (See Transmit Selection on page 50)
and can be included in a custom transmit (See Custom Transmit Setup on page 55).

Upon power up and with P502 set to Enabled, the display will toggle Enter ~ Date~01.01.70. If the date

is acceptable, press the

1

.

To enter the date from the Enter~date~01.01.70 prompt

EXAMPLE: 01.09.04 (January 9, 2004)

1. Press



to toggle through the numbers to enter the month.

DISPLAY READS X 1

Advertising