DT 200 Users Manual version 1.E

Set Operation Parameters

28

Enter a 0 to disable TTL remote control.

Battery, Watch Dog Timer

Parameter 41 Battery Backup (0 [no])

The battery is used to preserve the time and date, memory registers, and ID memory

when power is lost. Set the Battery Backup parameter to ON (1) to prevent the DT200

from clearing memory when power is restored, set parameter 41 to OFF (0) to erase

memory when power is restored.

Parameter 42 Enable Watch Dog Timer (0 [no])

The watchdog timer resets the DT200 when the weight display is not updated within the

time-out time (0.2 sec). Set the Enable ON (1) to reset after time-out. Set the Enable

OFF (0) to turn off the watchdog timer.

Parameters 43-50 Fixed Registers

The Fixed Registers are used by the Trip-Level Event Monitor to determine when a trip-

level is reached. See the “Scale Basic / Event Monitor” manual for more information.

Parameters 43 thru 50 select Fixed Setpoints 1 thru 8. Select the parameter number to be

changed and then enter the trip-level weight.

Parameters 51-58 Keyboard Event Functions

The keyboard event functions determine what actions take place when a key is pressed.

The Power on start function activates a function when power is applied to the indicator.

Number Parameter Name

Default Value

Password

51

Power on start function

0 (no function executed)

2

52

PRINT key function

136 (Print function)

2

53

UNITS key function

127 (Units toggle function)

2

54

Gross/Net key function

128 (Gross/Net toggle)

2

55

TARE key function

129 (Tare function)

2

56

ZERO key function

0 (no function)

2

57

Function Key 1 (F1)

0 (no function executed)

2

58

Function Key 2 (F2)

0 (no function executed)

2