Industrial Data Systems IDS DT200 User Manual

Page 38

Advertising
background image

DT 200 Users Manual version 1.E

Diagnostic Tests

34

Print Format Design Example
EXAMPLE PRINT:

EXAMPLE FORMAT DESIGN WORKSHEET:

Page:1 Item Description

Line No.

Column Item No.

E1

Gross Weight

3

4

5

E2

Tare Weight

4

4

6

E3

Net Weight

5

4

7

E4

Time and Date

7

1

10

E5

End of Print

0

0

0

NOTE: A zero in the Line No column terminates printing. Use zero only after all

required information has been entered. The maximum number of entries is 16. If the 16

th

entry is used, a line number 0 is not required.

Default Print Formats
The print formats (PAGES) are initialized to the following factory settings when the

DT200 is initialized.

Page 1 Item Description

Line No. Column Item No.

E1

The Displayed Weight

1

1

18

E2

End of Print

0

0

0

Page 2 Item Description

Line No. Column Item No.

E1

Gross Wt. (primary units)

3

5

5

E2

Tare Weight (primary units)

4

5

6

E3

Net Weight (primary units)

5

5

7

E4

End of Print

0

0

0

1111111111222222222233333333334

COLUMN 1234567890123456789012345678901234567890

LINE
1

2

3 GROSS 54785 LB

4 TARE 12451 LB

5 NET 42243 LB

6

7 TIME 03:45 PM DATE 05 AUG 1999

Advertising