Cable Form

The cable has to be in one piece from end to end. It is not allowed to put more pieces together. Cables to

ISDN, Analogue or E&M devices must be shielded and have to be equipped with ferrite cores provided by

Kofax. The cores must be mounted as near as possible to the KCS Server. The cable has to be wound

around the core twice (turns as far apart as possible). Cabling has to be 26 AWG (0,13mm²) size as a

minimum.

Cabling Work

The cabling work cannot be performed by your KCS engineer.

Please have this work done by your company electrician.

On each end there have to be some meters left for later movements, plug mounting and maintenance.