Basic setups and operations – Casio CE-2400 User Manual

Page 34

Advertising
background image

34

Basic Setups and Operations

To program PLU links to departments, tax calculations and PLU/sub-department specifications

1 After you press the

c

key, you can loop back and start programming for another PLU by inputting a new PLU number.

2 When you press the

c

key, you can loop back and input another specification which will be assigned to the next PLU.

3 Press the

c

key again to program the next PLU number with the same specification.

4 All PLUs are initialized as no tax calculation.

to

PLU No.

Use all four digits

1

2

3

fi‚‚

s

p

c

s

OW

A-A08

Mode Switch

Z

X

REG

OFF

RF

Tax table

This specification defines which tax
table should be used for automatic
calculation of taxes. See page 21 for
information on setting up the tax
tables.

Tax table 1

2

¤

Tax table 2

2

Tax table 1 and 2

2

fl

No tax calculation

2

Sub-department/PLU specification

Treat as a PLU

2

Treat as a sub-department

2

A PLU can register its preset unit price
only. A sub-department can register
its preset price or a manually entered
price.

Linked department

This specification links the PLU to
a department.

Department 1

2

‚⁄

Department 2

2

‚¤

Department 3

2

‚‹

Department 4

2

‚›

Department 5

2

‚fi

:

:

:

Department 36

2

‹fl

Department 37

2

‹‡

Department 38

2

°

Department 39

2

‹·

Department 40

2

›‚

Non link

2

‚‚

Advertising