This section describes what to do when you have problems with operation.

When an error occurs...

Errors are indicated by an error tone. When this happens, you can usually find out what the problem is as illustrated
below.

Error Tone

Check the display for an error code
(E01, E08, E11, E27, E38)

Did you make a
mistake in operation?

Is the Mode Switch in the
correct position?

Press the

C

key.

Press the

C

key.

Check the appropriate section
of this manual for the operation
you want to perform.

Set the Mode Switch to the
correct position (page 10).

Troubleshooting

Error codes

Error code

E01

E08

E11

E27

E38

Meaning

Mode switch position changed before finali-
zation.

Registration without entering a clerk number.
This error appears only when the clerk control
function is activated.

Registration attempted while the drawer of
the register is open.

Transaction cancel buffer is full.

READ/RESET operation without declaration
of cash in drawer. This error appears only
when the money declaration (cash in drawer
amount input) is required by programming.

Action

Return the mode switch to its original setting
and finalize the operation.

Enter a clerk number.

Shut the drawer before attempting to per-
form a registration.

Finalize the transaction.

Perform money declaration.