5.3 Final Filter
The optional final filter is shipped separately to avoid shipping
damage. Install as follows:

1. Slip the final filter housing over the DynaPure outlet until the top

edge of the outlet is approximately even with the break in the
sides of the final filter housing.

2. Fasten with the self-drilling screws provided.

3. Seal the joint on the inside with the caulk provided.

4. Set the final filter cartridge in the top of the housing and

latch in place.

1

Final Filter

Cartridge

Outlet

DynaPure

Outlet

Figure 3. Final Filter Installation