7

10.0 Troubleshooting

Code Number

Meaning

0-5 mA

No failure

6-8 mA

Power Supply out of Tolerance

8-10 mA

Copper out of Range

10-12 mA

Silver out of Range

12-14 mA

Gold out of Range

14-16 mA

Self diagnostic, failed replace board

16-18 mA

Invalid time/date

18-20 mA

Other errors

Error Codes

When a detectable failure occurs, the fail bit is set and the failure code

is populated. the failure codes have the following meaning:

11.0 SAAFShield Parts List

It is recommended that the following spare parts be stored at the

installation site for replacement purposes. Consult with your AAF

representative to determine actual quantities required.

Description

Part Number

Detecting Unit (DU)

392-803-101

Silver Sensor

392-803-010

Gold Sensor

392-803-011

Copper Sensor

392-803-012

Reading Unit (RU)

392-803-001

Connection Cable (DU-RU)

392-803-003

12V Adaptor

392-803-000

Communications Module (CM)

- configured for Legacy

392-803-510

- configured for RoHS

392-803-520

- configured for Museum

392-803-530

Connection Cable (DU-CM)

392-803-004


to order replacement parts call: 1-800-AAF-2003.