4 preparation of coil gaskets, He-109 – AERCO Coil & Riser Replacement User Manual

Page 10

Advertising
background image

PR2: 04/01/11 Page 10 of 16

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288

Coil/Riser Replace Instructions for Helitherm Water Heaters

Technical instructions

TID-0038_0A

HE-109


TOP VIEW

1/8" MINIMUM

1/8" TO 1/4"

1/8" TO 1/4"

SIDE VIEW

1/8" MINIMUM

Figure 4: Coil Assembly Spacing

6.4 Preparation of Coil Gaskets

Two 6-tab gaskets are provided with each replacement Coil Assembly. Proceed as follows:





Preparation of Coil Gaskets

1) Form the Gasket into a round shape
2) Using Needle-Nose Pliers, form the 6 tabs on each Coil Gasket by bending each tab outward 2 to 3

degrees as shown in Figure 5. This will secure the Gasket into the Spud’s inside diameter.


Section 6.4 Instructions

END