He-109, Figure 6: sub-cooling coil alignment – AERCO Coil & Riser Replacement User Manual

Page 12

Advertising
background image

PR2: 04/01/11 Page 12 of 16

AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288

Coil/Riser Replace Instructions for Helitherm Water Heaters

Technical instructions

TID-0038_0A

HE-109

B*

A*

LOWER HEAD

SUB-COOLING

COIL

CONDENSATE

RISER

* MEASUREMENTS A & B SHOULD BE EQUAL

STUD

STUD

Figure 6: Sub-Cooling Coil Alignment

Figure 7: Assembly of Coil to Steam Riser or Condensate Return

STEAM RISER OR

CONDENSATE RETURN

UNION NUT

COIL GASKET

BOX

HEADER

SPUD