Group 200 (deleting codes), Group 300 (miscellaneous) – American Access Systems Advantage DKSII - Raintight Unit - 24-1000D User Manual

Page 12

Advertising
background image

Page 12 American Access Systems / Security Brands, Inc.

GROUP 200 (DELETING CODES)

“200”

SubMode 200 (DELETE CODES)

To delete any code from memory, with the exception of the MASTER CODE, enter the 5 digit “MASTER CODE” followed

by submode “200” and then the code to be deleted.

(MASTER CODE) + 200 + (CODE TO BE DELETED) + (NEXT CODE TO BE DELETED) etc...(# to exit)
You may continue deleting codes in a successive manner. When you are finished press # to exit. Should you make

an entry error, simply press the * key and reenter the correct data. Should you receive an ERROR after you enter a

code to be deleted, the code was not found in memory and the unit will wait for you to enter another code to be
deleted. The unit will respond with a GOODBEEP after each successful deletion.

“299”

!!!! WARNING ALL CODES WILL BE DELETED !!!!

SubMode 299 (CLEAR MEMORY)

To erase all codes from memory, (except the master code), enter the 5 digit “MASTER CODE” followed by submode

“299” and then reenter the 5 digit “MASTER CODE”.

(MASTER CODE) + 299 + (MASTER CODE)
The LED’s will flash on and off while the memory is being cleared and the unit will respond with a GOODBEEP when

finished. Should you make an entry error, simply press the * key and reenter the correct data. An ERROR will occur
and the unit will exit the program mode if the second master code is incorrect.

GROUP 300 (MISCELLANEOUS)

“300”

SubMode 300 (SET RELAY A OUTPUT TIME)
DESCRIPTION: The output time of relay A can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2

second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output

time may be desired.

To set the output time of relay A in seconds enter the 5 digit “MASTER CODE” followed by submode “300” and then a 2

digit number corresponding to the number of seconds.

(MASTER CODE) + 300 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been

accepted. If you enter 00 for seconds the output time is set to 1/2 second. Should you make an entry error, simply
press the * key and reenter the correct data.

“301”

SubMode 301 (SET RELAY B OUTPUT TIME)
DESCRIPTION: The output time of relay B can be set anywhere from 1/2 to 99 seconds. The factory default is 1/2

second. In most cases this is adequate for gate operators. However, with door strikes and maglocks a longer output

time may be desired.

To set the output time of relay B in seconds enter the 5 digit “MASTER CODE” followed by submode “301” and then a 2

digit number corresponding to the number of seconds.

(MASTER CODE) + 301 + (SECONDS)
The unit will respond with a GOODBEEP and exit from the program mode once the seconds for relay B has been

accepted. If you enter 00 for seconds the output time is set 1/2 second. Should you make an entry error, simply press
the * key and reenter the correct data.

“302”

SubMode 302 (SET CLOCK TIME)

To set the clock time enter the 5 digit “MASTER CODE” followed by submode “302” then the “HOURS” and “MINUTES” of

the day in military format.

(MASTER CODE) + 302 + (HOURS) + (MINUTES)

Example:

8:23 a.m. = “08” + “23”

5:00 p.m. = “17” + “00”

The unit will respond with a GOODBEEP and exit from the program mode after the TIME has been accepted into the

unit. Should you make an entry error, simply press the * key and reenter the correct data.

Advertising
This manual is related to the following products: