“404”

SubMode 404 (RED PRINTING ON INVALID CODES)
This option is only available if you are using an AAS OM-200 printer. The option will print out every invalid code in red.
This feature is disabled by default. To toggle this feature on or off press:

(MASTER CODE) + 404(*) + (MASTER CODE)

(*) 1 BEEP AND RED LED ON = FEATURE ENABLED

(*) 2 BEEP AND RED LED OFF = FEATURE DISABLED

“405”

SubMode 405 (PRINT OUT CURRENT UNIT CONFIGURATION)
This is a very convenient way to see what is the ADVANTAGE RCG current configuration. This will print out the status
of 3 Strikes Your Out, Split Relay, APB, Quiet Mode, Latch A Code, Latch B Code, Sleep Code, Manager’s Codes, and
Second Relay Codes. To print out the configuration press:

(MASTER CODE) + 405

“406”

SubMode 406 (PRINT OUT LAST 100 TRANSACTIONS)
This is a very convenient way to see the last 100 transactions instead of printing the entire history using Sub-Mode 400.
To print out latest 100 transactions press:

(MASTER CODE) + 406

“499”

SubMode 499 (CLEAR HISTORY BUFFER)
To clear the entire contents of the history buffer enter the 5 digit “MASTER CODE” followed by submode “499” and
then reenter the 5 digit “MASTER CODE”.

(MASTER CODE) + 499 + (MASTER CODE)

The LED’s will flash on and off and respond with a GOODBEEP when finished. Should you make an entry error, simply

press the * key and reenter the correct data.