AXEON Marathon Motor User Manual

Page 11

Advertising
background image

Nameplate Ambient Temperature above 65°C (150°F): Dow
Corning DC44 or equivalent, a special high temperature grease is
required. Note that Dow Corning DC44 grease does not mix with
other grease types.

4.2.2

BEARING OPERATING TEMPERATURE:

CAUTION:

HOT SURFACE

The external surface temperature of the end shield (bracket) bearing
hub may reach 100° C (212° F) during normal operation. Touching
this surface may cause discomfort or injury. Surface temperatures
should only be measured with suitable instruments and not estimated
by hand touch.


For RTD settings see Table 3-7.









_________________________________________________________________________________________________________________________

4.2.3

LUBRICATION INTERVALS: (For motors with regreasing provisions)

Eq. 4.2 Lubrication Interval = [(Table 4-1) hrs] x [Interval Multiplier (Table 4-2)] x [Construction Multiplier (Table 4-3)]

Table 4-1 Lubrication Intervals (Hours) These values are based on average use.

Operating Speed – RPM (See Table 3.4 for Maximum Operating Speed)

NEMA / [IEC] Frame Size

<7200

<5400

<4500

<3600

<1800

<1200

56-180 [80-110]

2500 Hrs.

4000 Hrs

5000 Hrs

6000 Hrs.

17000 Hrs.

20000 Hrs.

210-250 [130-160]

2500 Hrs

4000 Hrs

5000 Hrs.

12000 Hrs.

16000 Hrs.

280 [180]

2000 Hrs

3000 Hrs

4000 Hrs.

10000 Hrs.

14000 Hrs.

320 [200]

2000 Hrs

3000 Hrs.

9000 Hrs.

12000 Hrs.

360 [225]

1500 Hrs

2000 Hrs.

8000 Hrs.

10000 Hrs.

400-440 [250 – 280]

1500 Hrs.

4000 Hrs.

7000 Hrs.

>440 [>280]

1000 Hrs.

3000 Hrs.

5000 Hrs.

Seasonal Service: If motor remains idle for more than six months, Lubricate at the beginning of the season, then follow lubrication interval.

Do not exceed maximum safe operating speed Table 3-4 without manufacturer’s approval

Table 4-2 Service Conditions

Use highest level Multiplier

: Maximum Ambient Temperature and Contamination are independent factors

Severity of

Service

Maximum Ambient

Temperature

Atmospheric Contamination

Multiplier

Standard

Less than 40° C (104° F)

Clean, Slight Corrosion, indoors, less than 16 hrs per day

1.0

Severe

Above 40° C (104° F) to 50°

C

Moderate dirt or Corrosion or outdoors or more than 16 hrs

per day

0.5

Extreme

Greater than 50° C or

Class H Insulation

Severe dirt or Abrasive dust or Corrosion

0.2

________________________________________________________________________________________________________________________

Table 4-3 Construction Multiplier

Construction

Multiplier

Angular Contact or Roller Bearing

0.5

Vertical Motor

0.5

All others

1.0









Table 4-4 Relubrication Amounts

Frame Size

Volume

NEMA

IEC

Cu. In.

Fluid oz

ml

48-56

80

0.25

0.14

4.0

143-145

90

0.25

0.14

4.0

182-184

110

0.50

0.28

8.0

213-215

130

0.75

0.42

12.5

254-256

160

1.00

0.55

16.0

284-286

180

1.50

0.83

25.0

324-326

200

2.00

1.11

33.0

364-365

225

3.00

1.66

50.0

404-405

250

3.80

2.11

62.0

444-449

280

4.10

2.27

67.0

>449

>280

4.50

2.50

74.0

For regreasing while operating multiply volume by 125%.