Troubleshooting, Wiring diagrams – Braeburn 3200 User Manual

Page 6

Advertising
background image

10

Rc Rh

Y

Factory Installed

Jumper

MODEL 3000: Conventional Systems (Single Transformer)

W

G

B

O

24 Volt AC

Transformer

120

Volt AC

Hot Side

Transformer

Rc Rh

Remove

Factory Installed

Jumper

MODEL 3000: Conventional Systems (Dual Transformer)

Cool 24 VAC

Transformer

Heat 24 VAC

Transformer

120

Volt AC

120

Volt AC

Hot Side

Heat

Transformer

Hot Side

Cool

Transformer

Rc Rh

Factory Installed

Jumper

MODEL 3000: Heat Pump Systems

Reversing Valve

(Active in Heating

- See NOTE 2)

Fan

Control

120

Volt AC

Hot Side

Transformer

NOTES:

1. Transformer Common connection not required for battery-only operation

of thermostat. 2. For Heating or Cooling Only system, ignore opposite connection.

3. For 2-wire 24 Volt AC or 250mv - 750mv Millivolt Heating Systems, ignore cooling

connection and fan control.

Troubleshooting

8

cont.

Wiring Diagrams

9

C

Transformer Common

(See NOTE 1)

Y

W

G

B

O

C

Transformer Common

(See NOTE)

NOTE:

Transformer Common connection not required for battery-only

operation of thermostat.

NOTES:

1. Transformer Common connection not required for battery-only operation

of thermostat. 2. For units requiring reversing valve to be energized during heating,

connect reversing valve to B terminal. For units requiring reversing valve to be energized

during cooling, connect reversing valve to O terminal.

Y

W

G

B

O

C

Transformer Common

(See NOTE 1)

Reversing Valve

(Active in Cooling

- See NOTE 2)

Wiring Diagrams

9

cont.

11

Cool

Control

Heat

Control

Fan

Control

Cool

Control

Heat

Control

Fan

Control

24 Volt AC

Transformer

Compressor

Control

Symptom: Cannot program a set point temperature higher than 90˚ F (32˚ C).

Potential Solution: This is above the normal thermostat temperature setting
range of 45˚ to 90˚ F (7˚ to 32˚ C).

Symptom: Cannot program a set point temperature lower than 45˚ F (7˚ C).

Potential Solution: This is below the normal thermostat temperature setting
range of 45˚ to 90˚ F (7˚ to 32˚ C).

Symptom: Thermostat will not allow me to change the set point.

Potential Solution: The keypad is locked. Press either the or key and the
backlight key at the same time to unlock.

Symptom: Fan continues to run all the time whether the system is on or off.

Potential Solution: Check to make sure the fan control switch is in the AUTO
position. This will allow the fan to run only when the heating or cooling system is
turned on and running.
Check thermostat wiring to make sure that the fan control wiring is connected to
the correct terminals on the wiring terminal block. See Section 9.

Symptom: CHECK is shown in thermostat display.

(model 3200 only)

Potential Solution: Switch to emergency heat
if heat is required. Please contact a professional
service technician to verify thermostat and
system performance.

Symptom: NO EM HEAT SET is shown in the

thermostat display. (model 3200 only)

Potential Solution: The thermostat (model 3200
only) is configured for a conventional system,
and the system switch is in the

EM HEAT position.

The unit will still function in a conventional 2
stage

HEAT mode, but the display will flash NO

EM HEAT SET. Move the system switch to the HEAT position.