3000 12_warranty, Limited warranty, Year – Braeburn 3200 User Manual

Page 7: Premier series, Non-programmable thermostats, Wiring diagrams, Store this manual for future reference

Advertising
background image

R

O

B

C

Y1

Y2

E/W1

W2

G

L

1st Stage

Compressor

Control

2nd Stage

Heat

Control

Reversing

Valve (Active

in Heating-

See NOTE 4)

2nd Stage

Compressor

Control

(if equipped)

Emergency

Heat Control

(if equipped)

Reversing

Valve (Active

in Cooling-

(See NOTE 4)

System

Monitor

(if equipped)

See

NOTE 2

24 VAC

Neutral

120 VAC

Hot

Transformer Common

(See NOTE 1)

MODEL 3200: Heat Pump Systems

NOTES:

1. Transformer Common connection not required for battery-

only operation of thermostat. 2. User installed Jumper is required to use Auxiliary

heat for both second stage and emergency heat on units without separate

emergency heat and auxiliary heat terminals. DO NOT install jumper if both

terminals are present. 3. Eliminate connection to Y2 for units with single stage

cooling. 4. For units requiring reversing valve to be energized during heating,

connect reversing valve to B terminal. For units requiring reversing valve to be

energized during cooling, connect reversing valve to O terminal.

Wiring Diagrams

9

cont.

12

Fan Control

MODEL 3200: Conventional Systems

R

O

B

C

Y2

E/W1 W2

G

Y1

2nd Stage

Heat Control

1st Stage

Heat Control

Fan Control

Transformer Common (See NOTE 1)

24 VAC

Neutral

Hot

120 VAC

L

1st Stage

Compressor Control

2nd Stage

Compressor

Control

(See NOTE 2)

NOTES:

1. Transformer Common connection not required for

battery-only operation of thermostat. 2. Eliminate connection to Y2 for

units with single stage cooling.

©2011 Braeburn Systems LLC • U.S. Patents D524,663; D536,271; 7,438,469 • All Rights Reserved.
Made in China • 3000-100-010

Braeburn Systems LLC
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)

Premier Series

Non-Programmable Thermostats

Braeburn Systems LLC warrants each new Braeburn thermostat against any defects that are

due to faulty material or workmanship for a period of five years after the original date of

purchase by a professional service technician. This warranty and our liability does not apply to

batteries, nor does it include damage to merchandise or the thermostat resulting from

accident, alteration, neglect, misuse, improper installation or any other failure to follow

Braeburn installation and operating instructions.
Braeburn Systems LLC agrees to repair or replace at its option any Braeburn thermostat

under warranty provided it is returned postage prepaid to our warranty facility in a padded

carton within the warranty period, with proof of the original date of purchase and a brief

description of the malfunction. This limited warranty does not include the cost of removal or

re-installation.

WARRANTY FACILITY: Braeburn Systems LLC

Attn: Warranty Department

2215 Cornell Avenue

Montgomery, IL 60538

Store this manual for future reference.

LIMITED WARRANTY

5

YEAR

WARRANTY

LIMITED

This warranty gives you specific legal rights and you may also have other rights that vary from

state to state or province to province. Answers to any questions regarding our limited warranty

may be obtained by writing our corporate offices.

Advertising
This manual is related to the following products: