All system types, Attaching the thermostat to the sub-base, Additional wiring options – Braeburn 6400 Installer Guide User Manual

Page 7: 7 installer guide

Advertising
background image

7 Installer Guide

All System Types

Additional Wiring Options

NOTE: Additional options are configured in the Installer Settings section.

S1

Indoor or Outdoor Remote Sensor

[note 1]

S2

Indoor or Outdoor Remote Sensor

[note 1]

A/D* Economizer Control (6300, 6400 only) /

Dehumidifier Output (6400 only)

[note 2]

H

Humidifier Output (6400 only)

[note 3]

* This terminal appears as A on the 6300 and A/D on the 6400.

NOTES - Additional Wiring Options

[1] These terminals can be used to connect a Braeburn

®

indoor or outdoor remote sensor.

[2] This terminal can be used either for outside air control (6300 and 6400) or to connect to an external

dehumidifier (6400 only).

[3] This terminal can be used to connect an external humidifier (6400 only).

Attaching the thermostat to the sub-base

1) Line up the thermostat body with the sub-base.
2) Carefully push the thermostat body against the

sub-base until it snaps in place.

NOTE: This thermostat ships configured as a 1H/1C conventional

thermostat. Confirm installer settings. See page 10.

UP

UP

S1

S2

G

Y1

Y2

A

H

L

C

W1/E

/AUX1

W2/

AUX2

W3/

O/B

RH

RC

W1/E

/AUX1

G

RESET

RESET

3) Insert Quick Reference Card into slot

on top of thermostat.