Conventional systems, Additional wiring options – Braeburn 3220 Installer Guide User Manual

Page 5

Advertising
background image

5 Installer Guide

Heat Only or Millivolt

Set System Type to 11CONV

Rh Power Connection
W1 Heat Relay

G Fan Relay [note 4]

C 24 Volt AC Transformer Common [note 1]

1 HEAT / 1 COOL Single or Dual Transformer

Set System Type to 11CONV

Rh 24 Volt AC Power (heating transformer) [note 2]
Rc
24 Volt AC Power (cooling transformer) [note 2]
W1
Heat Relay
Y1 Compressor Relay
G Fan Relay
C 24 Volt AC Transformer Common [note 1, 3]

NOTES - Conventional Systems

[1] Optional 24 Volt AC common connection.
[2] Remove factory installed jumper for dual

transformer systems.

[3] In dual transformer systems, transformer

common must come from cooling transformer.

[4] If needed for system.
Provide disconnect and overload protection as required.

2 HEAT / 2 COOL Single or Dual transformer

Set System Type to 22CONV

Rh 24 Volt AC Power (heating transformer) [note 2]

Rc 24 Volt AC Power (cooling transformer) [note 2]

W1 Heat Relay Stage 1
W2 Heat Relay Stage 2
Y1 Compressor Relay Stage 1
Y2 Compressor Relay Stage 2 [note 4]
G
Fan Relay
C 24 Volt AC Transformer Common [note 1, 3]

Typical Wiring Configurations

NOTE: The “System Type” option will be configured in the Installer Settings section. The 3020 is a single stage

thermostat and not intended for multi stage equipment.

Conventional Systems

NOTE: Additional options are configured in the

Installer Settings section.

S1
S2

NOTES - Additional Wiring Options

[1] These terminals can be used to connect a

Braeburn

®

indoor or outdoor remote sensor.

Additional Wiring Options

Indoor or Outdoor Remote Sensor

[note 1]

Hydronic Heat Only

Set System Type to 1HD

Rh 24 Volt AC Power (heating transformer)
W1 Zone Valve Power Open
V3 Zone Valve Power Close

G Fan Relay [note 4]

C 24 Volt AC Transformer Common [note 1]

Hydronic Heat / 1 Cool

Set System Type to 11HD

Rh 24 Volt AC Power (heating transformer) [note 2]
Rc
24 Volt AC Power (cooling transformer) [note 2]
W1
Zone Valve Power Open

V3 Zone Valve Power Close

Y1 Compressor Relay

G Fan Relay (cooling fan only)

C 24 Volt AC Transformer Common [note 1, 3]

Advertising