Burris XTR II User Manual

Page 5

Advertising
background image

“0”. With the screws loose, push down firmly on the
knob until it is fully seated on the turret base and then
retighten the set screws.

NOTE: Windage adjustments
are made with a multi-direction
adjustment knob. Zero is set
with an indexing mark to allow
for left and right adjustments.
Failure to zero at the index
mark may result in limited
windage adjustment.

Windage/Elevation Adjustment for Single-Turn Knobs
– Applies to 1x-5x and 1.5x-8x models –
The windage and elevation knobs are designed for
precise adjustment. The click value for each knob is
indicated on the dial.

The elevation knob at the top of the tube provides 9.3
mRAD of adjustment in one full turn and features a
Zero Stop. The windage knob, located on the right side
of the tube, provides up to 4.6 mRAD of adjustment in
both directions.

Both knobs can be reset to “0”
once the scope is sighted-in. To
reset the knobs to “0,” use the
hex wrench supplied with the
scope to loosen the set screws
located at the top of the
adjustment knobs.

The dial should spin freely.
Rotate the knob until the “0”
lines up with the hash mark
indicator, and then retighten
the set screws. The knob is not
intended to come up or off, but
if the set screws are loosened too far, the knob can be
removed. The scope is still fully sealed if this does
accidentally occur.

4

Proper Windage Zero

Advertising