CompuSTAR CM1000A User Manual

Page 8

Advertising
background image

13

CON 1

14

CM1000A Wiring Diagram

trunk
Solenoid

trunk Release Switch

CON1-4

Red : 12v Constant Input
Constant 12-volt (+) positive power input for the control module. This wire
must be connected to a constant 12-volt (+) positive source. The proper wire
will test 12-volt (+) positive with the key in the off position, while key is in the
on position and during crank.

Violet : (+) Parking Light Output

Connect this wire to the (+) positive parking light wire generally at the parking

light switch or behind the fuse box. The proper wire will test 12-volts (+)

positive when the parking light switch is in the on position.
Brown : (+)12v Siren Output

This wire will provide a 30 second (+) positive output for the external siren.

Gray : (+)12v Trunk Output
This wire will provide a (+) positive trigger pulse. (Note: Negative trigger trunk
release will require a relay. System will unlock doors and disarm alarm prior
to trunk release.)

Black : Chassis Ground

This wire will connect to chassis ground. This is one of the most important

connections you will make. Choose a factory grounding point or strip back the

paint before grounding. We do not recommend using the steering column.

Proper grounding is crucial to preventing future problems.

Advertising