Section 7 – routine maintenance – CAMCORP Baghouse Collector User Manual

Page 53

Advertising
background image

CAMCORP, INC.

Phone: 913-831-0740 Fax: 913-831-9271

www.camcorpinc.com

Section 7 – Routine Maintenance

Inspection

Frequency will vary as widely as there are operating conditions. In
general proceed as follows:

Daily – Check unit differential pressure.

Weekly – Check pulse timer board and solenoid valves for function.
This usually is only listening to check uniform time in intervals between
blasts.

Monthly – Lubricate fan, rotary valve and screw conveyor. Check seals
on latter two for dust loss.

Quarterly – On Top Access Units, check for dust accumulation in clean
air plenum.

Repairs

Filter bags – Generally replacement, although some applications can be
laundered.

Solenoid Valves – Repair kits are available if a valve is stuck open or
fails to operate.

Diaphragm Valves – Repair kits are available if a valve is stuck open or
fails to operate due to a ruptured diaphragm.

Rotary Valves – Usually a matter of periodic seal and blade
replacement. More detailed information is supplied with the valve.

Screw Conveyors – Periodic replacement of “V” belts and shaft seals.
Inspect hanger bearings during filter bag change. Failure will be
detected by the squeal.

Fans – “V” belt tension and replacement of bearings if running rough.
Make sure rotor balance is maintained.




7-1