How to sanitize the storage tank

You will need to order Tank Sanitizing Kit, Part No.
4373527. You will also need household bleach and
a measuring spoon.

1. Turn off saddle valve in water line. Open faucet
and drain storage tank. There will be no water dripping

when tank is empty.

2

.

Turn off faucet. Push in grey connector to disconnect

yellow tubing from system. Connect yellow tubing to push
in connector on side of sanitizing kit.

3

.

Disconnect orange tubing from filtration assembly.

Connect orange tubing to tank sanitizing kit’s other
push-in connector.

4

.

Put

1/2

teaspoon of bleach into tank sanitizing kit.

5

.

Turn on saddle valve in water line. Allow storage

tank to fill for about 3 minutes. Turn off saddle valve in
water line and the valve at the top of storage tank.

6

.

Wait 15 minutes. Disconnect tank sanitizing kit

from storage tank. Disconnect the orange tubing from
the tank sanitizing kit.

7

.

Reconnect orange tubing to filtration assembly.

Reconnect yellow tubing to filtration system.

8

.

Turn on saddle valve in water line and the valve

at top of storage tank. Open faucet and drain tank.
There will be water dripping when the tank is empty.

9

.

Allow tank to refill. Wait about 6 hours. Drain tank

again and allow it to refill. If water has a taste, drain
tank and allow it to refill again.

Preparation for long periods of non-use

Follow these instructions if RO system will not be used
for more than 30 days.

1. Turn off saddle valve in water line. Open faucet to

drain tank. There will be no water dripping when
tank is completely empty. Wait five minutes for filtration
assembly to depressurize.

2

,

Remove all cartridges. Place cartridges upside-

down in sink or bucket to drain water from cartridges.

Place cartridges in a plastic bag and seal tightly. Place
bag with cartridges in refrigerator.

DO NOT allow

cartridges to freeze.

Using RO system after long periods

of non-use

1

. Follow instructions for replacing cartridges.

2

.

Sanitize storage tank.

3

.

Sanitize RO System.

4

.

Follow “Flush System" instructions.

Call 1-800-253-1301 to order.

If You Need Assistance...

The Whirlpool Consumer Assistance Center will answer any questions about
operating or maintaining your RO water filtration system not covered in
the Installation Instructions/Use and Care Guide. The Whirlpool Consumer
Assistance Center is open 24 hours a day, 7 days a week. Just dial
1-800-253-1301 -the call is free.

When you call, you will need the RO water filtration system model number
and serial number. Both numbers can be found labeled on the top right side
of the filtration assembly.

How To Arrange For Service...

In the event that your Whirlpool appliance should ever need service, call the

dealer from whom you purchased the appliance or a Whirlpool-authorized
service company. A Whirlpool-authorized service company is listed in the
Yellow Pages of your telephone directory under “Appliances-Major-Service
or Repair." You can also obtain the service company's name and telephone
number by dialing, free within the continental United States, the Whirlpool
Consumer Assistance Center telephone number, 1-800-253-1301. A special
operator will tell you the name and number of your nearest Whirlpool-
authorized service company.

Maintain the quality built into your Whirlpool appliance - call a Whirlpool-
authorized service company.

Ifi

Replacement Parts & Accessories

Replacement Cartridge Kit

Kil includes Sediment (S), GAC Carbon (GAC) and

Carbon Block (CB) Cartridges. Cartridges can also
be ordered individually. TPCM Membrane Cartridge
(RO) needs replacing only once every two years,
when indicator disk light turns yellow.

4373575

TFCM Membrane Cartridge (RO)

4373501

Sediment Cartridge (S)

4373502

GAC Carbon Cartridge (GAC)

4373503

Carbon Block Cartridge (CB)

4373504

SFC Flow Control (Red Tubing)

4373508

Filtration Assembly Cover

4373509

Storage Tank

4373511

Air Gap Faucet

4373522

Refrigerator Hook-up Kit

4373505

Additional Parts

Needed For Multiple
Connections:

%" Tubing •

4319151

“T" Connector with Push-in Ends

4319152

% Reiection Monitor

4373512

Flow Sensor

4373513

LED Faucet Base Assembly

4373514

Installation Instructions

4373500B

Installation Kit

4373518

Tubing Kit

4373519

Vi"

Green Tubing 4'

4373516

Spare “O" Ring Kit

4374515

Drain Saddle Assembly

4373520

Saddle Valve, Self-tapping

4373521

Basement Installation Kit

4373517

Booster Pump

4373525

Tank Sanitizing Kit

4373527

% Connector with Push-in Ends

4373546

Ya “T" Connector with Push-in Ends

4373547

Ya-'A Male Connector with Push-in Ends

4373548

Y

b

-V4 Reducing Connector with Push-in Ends

4373549

'U

Elbow Connector with Push-in Ends

4373556

Ya Elbow Connector with Push-in Ends

4373557

Whirlp<iol

/

^^CO«PO«AriON

MODEL IV REVERSE OSMOSIS DRINKING WATER TREATMENT UNIT

MODEL NO. WSR413YW

REPLACEMENT CARTRIDGE: WHIRLPOOL RO ESP# 4373501

WHIRLPOOL GAC ESP# 4373503

WHIRLPOOL S ESP# 4373502
WHIRLPOOL CB PSP# 437504

SERVICE PLOW RATE - 0.6 gpm (2.28 Ipm)
MAX. OPERATING PRESSURE -100 psig (862 kPa)
MIN. OPERATING PRESSURE - 40 psig (345 kPa)
MAX. OPERATING TEMPERATURE 100°E (38°C)

NOTICE: DO NOT USE WHERE WATER IS MICROBIOLOGICALLY UNSAPE OR WITH WATER OP UNKNOWN QUALITY.

THIS PRODUCT HAS BEEN TESTED AND LISTED UNDER NSP STANDARD 58 POR TOTAL DISSOLVED SOLIDS, ARSENIC,
BARIUM, CADMIUM, CHROMIUM, NITRATE, LEAD. MERCURY, RADIUM, AND SELENIUM REDUCTION. SEE PERPORMANCE
DATA SHEET POR PERMISSIBLE CLAIMS.

NITRATE REDUCTION MODELS ("NITRATE”) ARE ACCEPTABLE POR TREATMENT OP INPLUENT CONCENTRATIONS UP
TO 30 mg/L; ADDITIONAL TREATMENT SHALL BE REQUIRED POR HIGHER INPLUENT LEVELS.

THIS SYSTEM IS NOT CERTIPIED POR NITRATE REDUCTION IN WATER SUPPLIES WITH A PRESSURE
OP LESS THAN40PSI.

WHIRLPOOL CORPORATION, BENTON HARBOR, Ml, USA.

(NSF.

IT IS ESSENTIAL THAT OPERATIONAL, MAINTENANCE AND PILTER REPLACEMENT REQUIREMENTS
BE CARRIED OUT POR THE PRODUCT TO PERPORM AS ADVERTISED.--