Electrical connection, Four-wire connection, Warning – Whirlpool LTE5243DQ User Manual

Page 3: Power supply cord, Direct wire, Disconnect the power supply, Power supply cord direct wire

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

For use where
local codes
permit use of
flexible power
supply cord.

four-wire

receptacle

(14-30R)

Figure 3

three-wire

receptacle

(10-30R)

Figure 4

Four-wire installation is recommended
(required for mobile homes); The power

supply cord must have four. No.-10
copper wires and match a four-wire
receptacle of NEMA Type 14-30R (see

Figure 3). The fourth wire (ground

conductor) must be identified with a
green cover and the neutrai conductor

by a white cover.

Three-wire installation (if a four-wire
system is not available): The power
supply cord must have three. No.-10
copper wires to match a three-wire
receptacle of NEMA Type 10-30R (see
Figure 4).

Direct wire

The washer/dryer can be connected
directly to fused disconnect or circuit

breaker box with four-wire or three-wire

flexible armored or non-metallic
sheathed copper cable (with ground
wire). Do Not use two-wire with bare
ground wire. All current-carrying wires
must be insulated.

A conduit connector must be installed
at junction box, USE ONLY 10-GAUGE
SOLID COPPER WIRE. DO NOT USE
ALUMINUM WIRE. Allow four feet of slack

in the line so dryer can be moved if

servicing is ever necessary.

Electrical connection

C

-------LT

terminal block cover

Figure 5

This dryer is manufactured with the

cabinet-ground conductor connected
to the NEUTRAL (center) of of the wiring
harness at the terminal block, If local
codes do NOT permit this type of
connection, use "Four-wire connection"
instructions.
GROUND INSTRUCTIONS: This appliance
must be grounded. In the event of
malfunction or breakdown, grounding

will reduce the risk of electric shock by

providing a path of least resistance for
electric current,
If using power supply cord, the plug
must be plugged into an appropriate
outlet that is properly installed and
grounded in accordance with all local
codes and ordinances.

If using a direct wire connection, this
appliance must be connected to a
grounded metal, permanent wiring

system; or an equipment-ground
conductor must be run with the circuit
conductors and connected to the
equipment-ground terminal or lead on
the appliance,
WARNING - Improper connection of fhe
equipment-ground conductor can

result in a risk of electric shock. Check

with a qualified electrician or
serviceman if you are in doubt as to
whether the appliance is properly
grounded. Do not modify the power
supply cord plug. If it will not fit the
outlet, have a proper outlet installed by
a qualified electrician.

A.

Four-wire connection...

^WARNING

^WARNING

. Fire Hazard

Use a new UL approved 30 ampere
power supply cord.
Use a UL approved strain relief.
Disconnect power before making

electrical connections.
Connect neutral wire (white or center

wire) to center terminal (silver).
Ground wire (green or bare wire) must

be connected to green ground
connector.
Connect remaining 2 supply wires to

remaining 2 terminals (gold).
Securely tighten all electrical

connections.
Failure to do so can result in death,

fire, or electrical shock.

A

Fire Hazard

Use 10 gauge solid copper wire.
Use a UL approved strain relief.

Disconnect power before making

electrical connections.
Connect neutral wire (white or center

wire) to center terminal (silver).
Ground wire (green or bare wire) must

be connected to green ground
connector.
Connect remaining 2 supply wires to

remaining 2 terminals (gold).
Securely tighten all electrical

connections.

Failure to do so can result in death,

fire, or electrical shock.

POWER SUPPLY CORD

DIRECT WIRE

neutral (white or
center)

center silver-colored
terminal block screw

power
supply cord
ground
wire (green)

Internal cabiriet
ground
connector

Figure 6

appliance
harness ground
wire (green
with yellow
stripes)

.external

cabinet-
ground
connector

1. Disconnect the power supply.

2. Remove terminal block cover (see

Figure 5).

3. Install copper, four-wire power

supply cord through strain relief.

4. Remove the appliance harness

ground wire (green with yellow
stripes) from the internal ground
connector and fasten under
center, silver-colored terminal
block screw.

5. Connect the ground wire (green)

of the copper, four-wire power
supply cord to the internal ground
connector.

6. Connect the neutral wire (white) of

the power supply cord to the
center, silver-colored terminal
screw of the terminal block.
Connect the other wires to the
outer terminals. Tighten screws
firmly,

7. Tighten strain relief screws.
8. Replace the terminal block cover.

1. Disconnect the power supply.

2. Remove terminal block cover (see

Figure 5).

3. Strip 5 inches of outer covering from

end of cable. Leave bare ground
wire at 5 inches. Cut 1-1/2 inches
from 3 remaining insulated wires.
Strip insulation back 1 inch (see
Figure 7).

led of

10-gauge, 3-wire

with ground wire

(Romex)

r

Direct wire preparation

Figure 7

u-shaped
hook

Figure 8

Shape the end of
each wire info a "U"
shaped hook (see
Figure 8). The bare
ground wire must be
4-1 /2 inches long after
forming the hook.

4. Install copper, four-wire power

supply cable through strain relief.

5. Remove fhe appliance harness

ground wire (green with yellow
stripes) from the internal ground
connector and fasten under
center, silver-colored terminal block
screw.

6. Slide the hook end of the ground

wire (bare) of fhe four-wire power
supply cable under the internal
ground connector screw. Squeeze

hook end of wire together. Tighten

screw.

7. Connect the neutral wire (white) of

the power supply cable to the
center, silver-colored terminal
screw of the terminal block using
the same method. Connect the
other wires to the outer terminals.
Tighten screws firmly.

8. Tighten strain relief screws.
9. Replace the terminal block cover.

Panel B

Advertising