Location requirements, Carbon monoxide poisoning hazard, Fire or explosion hazard – Kenmore 153:331472 User Manual

Page 12: Site location, A warning, Fire and explosion hazard

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Location Requirements

A WARNING

Carbon Monoxide Poisoning Hazard

Do not install in a mobile home.

Doing so can result in carbon monoxide poisoning and death.

The FVIR System is designed to reduce the risk of flammable

vapor-related fires. The patented system protects your family by

trapping the burning vapors within the water heater combustion

chamber through the special flame-arrestor. The burning vapors

literally “burn themselves out” without escaping back into the

room. In the event of a flammable vapor incident, the FVIR

System disables the water heater by shutting off the gas supply

to the water heater’s burner and pilot, preventing re-ignition

of any remaining flammable vapors in the area. This will not

prevent a possible fire/explosion if the igniter is depressed

and flammable vapors have accumulated in the combustion

chamber with the pilot light off. If you suspect a flammable

vapor incident has occurred, do not use this appliance. Do not

attempt to light this appliance, or depress the igniter button

if you suspect flammable vapors have accumulated inside or

outside the appliance. Immediately call a qualified technician to

inspect the appliance. Water heaters subjected to a flammable

vapors incident will show a discoloration on the flame-arrestor

and require replacement of the entire water heater.

A

FIRE AND EXPLOSION HAZARD

Can result in serious injury or death

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance. Storage of or use of gasoline or other
flammable vapors or liquids in the vicinity of this or any
other appliance can result in serious injury or death.

Read and follow water heater warnings and instructions.

Do not use or store flammable products such as gasoline,

solvents, or adhesives in the same room or area near the

water heater. If such flammables must be used, all gas burning

appliances in the vicinity must be shut off and their pilot lights

extinguished. Open the doors and windows for ventilation while

flammable substances are in use.

If flammable liquids or vapors have spilled or leaked in the

area of the water heater, leave the area immediately and call

the fire department from a neighbor’s home. Do not attempt to

clean the spill until all ignition sources have been extinguished.

A WARNING

Fire or Explosion Hazard

Read instruction manuai before instaiiing, using or

servicing water heater.

Improper use may resuit in fire or expiosion.

Maintain required ciearances to combustibies.

Keep combustibles such as boxes,

away from the water heater area.

Site Location

magazines, clothes, etc.

• Select a location near the center of the water piping system.

The water heater must be installed indoors and in a vertical

position on a level surface. DO NOT install in bathrooms,

bedrooms, or any occupied room normally kept closed.

• Locate the water heater as close to the chimney or gas

vent as practical. Consider the vent system piping and

combustion air supply requirements when selecting the

water heater location. The venting system must be able

to run from the water heater to termination with minimal

length and elbows.

• Locate the water heater near the existing gas piping. If

installing a new gas line, locate the water heater to minimize

the pipe length and elbows.

• The water heater should be located in an area not subject

to freezing temperatures. Water heaters located in

unconditioned spaces (i.e., attics, basements, etc.) may

require insulation of the water piping and drain piping

to protect against freezing. The drain and controls must

be easily accessible for operation and service. Maintain

proper clearances as specified on the rating plate.

• Do not locate the water heater near an air-moving device.

The operation of air-moving devices such as exhaust fans,

ventilation systems, clothes dryers, fireplaces, etc., can

affect the proper operation of the water heater. Special

attention must be given to conditions these devices may

create. Flow reversal of flue gases may cause an increase

of carbon monoxide inside of the dwelling (Figure 8).

• If the water heater is located in an area that is subjected to

lint and dirt, it may be necessary to periodically clean the

base-ring filter and flame-arrestor (see External Inspection

& Cleaning of the Flame-arrestor).

• This water heater is

not

for use in manufactured (mobile)

homes or outdoor installation.

NOTE: This water heater must be installed according to all local

and state codes or, in the absence of local and state codes, the

“National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.

FIGURE 8