if the flame is absent. This unit is also equipped with a thermal

switch, designed to shut off the gas supply in the event the

water heater has been exposed to flammable vapors (e.g.,

spilled gasoline), poor combustion caused by a blocked vent or

insufficient combustion air. If the thermal switch opens:
1. Check the flame-arrestor for signs of high temperature (blue

or black discoloration). See Figure 38.

2. If there are signs of high temperature or that the thermal switch

has opened, inspect your installation for problems with venting,

combustion air supply, or a possible flammable vapor event.

(See “Pilot Light Troubleshooting Flowchart” section.) Correct

any issues prior to resetting the thermal switch. If you suspect

a flammable vapor incident has occurred, do not use this

appliance. Immediately call a qualified technician to inspect

the appliance. Water heaters subjected to a flammable vapors

ignition will require replacement of the entire water heater.

3. Reset the thermal switch by depressing the small button in the

center of the thermal switch. Follow the Lighting Instructions

found on the front of your water heater. A high temperature

limit switch or ECO (Energy Cut Off) in the tank is used to

shut off the unit if the water temperature exceeds 195°F

(91 °C). The ECO is a single-use switch, which, if activated,

requires complete replacement of the entire gas control valve/

thermostat. If the ECO should activate, the water heater cannot

be used until the gas control valve/thermostat is replaced by

a qualified technician. Contact Sears at 1-800-4-MY-HOME

(1-800-469-4663) to request service.

Leakage Checkpoints

AWARNING

Read

and

understand

instruction

manual

and

safety

messages

before

installing,

operating

or

servicing this water heater.

Failure

to

follow

Instructions

and

safety

messages

could

result

in

death or serious injury.

Instruction

Manual

must

remain

with water heater.

FIGURE 43.

Read this manual first. Then, before checking the water heater,

make sure the gas supply has been turned “OFF”, and never

turn the gas “ON” before the tank is completely full of water.

Never use this water heater unless it is completely filled with

water. To prevent damage to the tank, the tank must be filled

with water. Water must flow from the hot water faucet before

turning “ON” gas to the water heater.
A. Water at the draft hood is water vapor which has condensed

out of the combustion products. This is caused by a

problem in the vent. Contact a qualified technician.

B. ‘Condensation may be seen on pipes in humid weather or

pipe connections may be leaking.

C. *The anode rod fitting may be leaking.
D. Small amounts of water from temperature-pressure relief

valve may be due to thermal expansion or high water

pressure in your area.

E. *The temperature-pressure relief valve may be leaking at

the tank fitting.

F. Water from a drain valve may be due to the valve being

slightly opened.

G. *The drain valve may be leaking at the tank fitting.
H. Combustion products contain water vapor which can

condense on the cooler surfaces of the tank. Droplets form

and drip onto the burner or run on the floor. This is common

at the time of start-up after installation and when incoming

water is cold.

I. Water in the water heater bottom or on the floor may be

from condensation, loose connections, or the relief valve.

DO NOT replace the water heater until a full inspection

of all possible water sources is made and necessary

corrective steps taken.

Leakage from other appliances, water lines, or ground seepage

should also be checked.
* To check where threaded portion enters tank, insert cotton

swab between jacket opening and fitting. If cotton is wet, follow

draining instructions in the “Draining and Flushing” section and

then remove fitting. Put pipe dope or teflon tape on the threads

and replace. When you are finished, follow the steps in “Filling

the Water Heater” in the Installation Instructions earlier in this

manual.