UPD765 signal description

MZ3500

Pin No.

Signal name

I/O

Function

40

Vcc

-

+5V

20

GND

-

0V

19

0

1

Single phase, TTL level clock

1

RESET

Set the FDC into an Idle state, and all drive unit interface outputs, except PSO. 1, and WDATA

(don't care), are set to low level In addition. INT and DRW outputs are set to low level DB goes

into an input state.

4

CS

1

Validates RD and WR signals

13 ~ 6

DB7 ~ DBO

I/O

Bidirectional, tri-state data bus

3

WR

1

Control signal to write data to the FDC via the data bus

2

RD

1

Control signal to read data from the FDC via the data bus

18

INT

0

The signal used to indicate a service request from the F DC It is issued at every byte in the non-

DMA mode, or upon completion execution of a command m the DMA mode

5

AO

1

The signal used to select the status register or data register of the FDC for access via the data
bus. When 0, it selects the status register When 1, it selects the data register.

14

DRQ

о

FDC to memory data transfer request signal in the DMA mode

15

DACK

I

The signal that indicates use of the DMA cycle During the DMA cycle, it functions identically

to CS.

29, 28

USO, 1

о

Drive unit select signal, with which up to four drive units can be selected.

26

MFM

0

The Signal used to designate the operation mode of the VFO circuit When 0. the MFM mode is

assigned. When 1, the FM mode is assigned

24

SYNC

о

The signal used to designate the operation mode of the VFO circuit When 1. it permits reading

operation. When 0, it prohibits reading operation

39

RW/SEEK

о

Signal used to discriminate the read/write signal from the seek signal that used for drive unit
interfacing signal. When 0, it indicates RW When 1, it indicates

36

HOLD

о

Signal used to load the read/write head

27

SIDE

о

Signal used to select head #0 and head #1 for the double-sided floppy disk drive unit. When 0,
it selects head 0. When 1, it selects head 1.

38

LCT/DIR

о

When the RW/seek signal is operating as RW, the signal works as LCT which indicates that the

read/write head is selecting the cylinder above 43. When the RW/SEEK is operating as SEEK,

it works as DIR which indicate seek direction When 0. seek is made towards outer side

When 1, seek is made towards inner side

37

FLTR/STEP

о

When the RW/SEEK signal functions as RW, it works as F LTR which resets any fault condition
as the seek step signal.

35

READY

1

Signal used to indicate that the drive unit is ready for operation

34

WPRT/2 SIDE

1

When the RW/SEEK signal is operating as RW, it furtction as WPRT which indicates that the drive

unit or the floppy disk is write protected. When the RW/SEEK is function as the SEEK signal

produces 2 SIDE which indicates that a double sided media is in use.

17

INDEX

'

Signal to indicate the physical start point of the track.

33

FLT/TRKO

1

When the RW/SEEK signal is operating as RW, it works as FLT which indicates that the drive

unit is in a fault condition. When the RW/SEEK is operating as SEEK, it works as TRKO
which indicates that the read/wnte head is on cylinder 0.

16

TC

1

Signal used to indicate the termination of a read or write operation

30

WDATA

о

Data written on the floppy disk consists of clock bits and data bits

25

WE

о

Signal to indicate write enable to the drive unit

21

WCLK

1

Data write timing signal which is 250kHz in the FM mode or 500kHz in the MFM mode