Notes – Sharp MZ-3500 User Manual

Page 88

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

M'Z ?50C

Type of error

(

1

)

MDF 1/F error

^

ON

OFF

Isec.

'•sec.

(2,'

SDO read/write error -

CD SDO bank alternation error

© AD2 bank alternation error

® AD3 bank alternation error

® ROM sum-check error

® Option RAM read/write error

(Indicated even when the option RAM is not in use)

^ Option RAM bank alternation error

NOTES:

1. The MFD l/F will not be tested, if there is no MFD l/F

connected or when the diskette was not inserted in the

slot of the drive unit No.2.

2.

ROM test will not be performed, unless it is a ROM

based machine.

2)

Loacing check program

The test program is loaded from the specified track and

sector to start executing the test.

[Procedure]

(1)

Set dip switches on of the 4 bit unit located in middle

of the front side of the board as illustrated at the right.

' No.

1

2

3

4

POSITION

OFF

ON

ON

ON

)

,2) Set dip switches on of the 2 bit unit located on the

front side of the board.

(3) Insert the media into a slot of any diskette drive unit.

(4) Turn the power on

(5)

Load the program from the specified track and sector,

to start execution of the test program.

[Conditions required for the drive unit and media]

(1) Use the FD-55B for the diskette drive unit.

(2)

Program may exist in any sector of any track, provided

that it is written in continuous sector within a same

track.

(Max. 256 bytes x 16 sectors = 4K bytes)

(3)

Data descrived next should have been written on

Sector 1 of Track 0.

(4) Program loading address must be 4800H and higher

- 95

Advertising